(iv) 03 command: This command reads all monitored data from the inverter.
- Transmission frame
Frame format
STX Station
No.
Command BCC
CR
Description
Data
size Setting
STX
Control code (Start of TeXt)
1 byte
STX (0x02)
Station No.
Station number of control-target
inverter
2 bytes
01 to 32
Command Command to be transmitted
2 bytes
03
BCC
Block check code
2 bytes
XOR of the items from "Station No." to "Data."
See Item (3) of this section.
CR
Control code (Carriage Return)
1 byte
CR (0x0D)
- Response frame
Frame format
STX Station
No. Data
BCC
CR
Description
Data
size Setting
STX
Control code (Start of TeXt)
1 byte
STX (0x02)
Station No.
Station number of control-target
inverter
2 bytes
01 to 32
Data
Data
104 bytes
See Note 7.
BCC
Block check code
2 bytes
XOR of the items from "Station No." to "Data."
See Item (3) of this section.
CR
Control code (Carriage Return)
1 byte
CR (0x0D)
Note 7: Monitored data
Monitoring item
Unit
Magnifica-
tion
Data size
Description
Output frequency
Hz
×
100
8 bytes Decimal ASCII code
Output current
A
×
10
8 bytes Decimal ASCII code
Rotation direction
-
-
8 bytes "0" stopping, "1" (forward rotation), or "2"
(reverse rotation)
PID feedback data
%
×
100
8 bytes Decimal ASCII code
Intelligent input terminal
-
-
8 bytes See Note 7.
Intelligent output terminal
-
-
8 bytes See Note 8.
Frequency conversion
-
×
100
8 bytes Decimal ASCII code
Output torque
%
×
1
8 bytes Decimal ASCII code
Output voltage
V
×
10
8 bytes Decimal ASCII code
Electric power
kW
×
10
8 bytes Decimal ASCII code
-
-
-
8 bytes Always "00000000" (reserved for data storage)
Cumulative running time
h
×
1
8 bytes Decimal ASCII code
Cumulative power-on time
h
×
1
8 bytes Decimal ASCII code
↑
High-orde
r
by
tes Low-order
b
ytes
↓
Note 8: Monitoring of intelligent input terminals
Note 8: Monitoring of intelligent output terminals
Terminal Data
Terminal Data
Terminal 1
00000001
Terminal 11
00000001
Terminal 2
00000002
Terminal 12
00000002
Terminal 3
00000004
Terminal 13
00000004
Terminal 4
00000008
Terminal 14
00000008
Terminal 5
00000010
Terminal 15
00000010
Terminal 6
00000020
Relay terminal
00000020
Terminal 7
00000040
Terminal 8
00000080
FW terminal
00000100
Содержание SJ700B SERIES
Страница 15: ...Contents xiii Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 45: ......
Страница 59: ......
Страница 223: ......
Страница 237: ......
Страница 245: ......
Страница 250: ...Chapter 7 Specifications 7 5 SJ700B 185 to 300HFF SJ700B 370HFF 5 Cable hole φ25 3 Cable hole 42 x 42 5 ...
Страница 251: ...Chapter 7 Specifications 7 6 SJ700B 450 to 550HFF 5 Cable hole φ41 ...
Страница 253: ......