Chapter 8 List of Data Settings
8 - 2
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
d025
User monitor 0
-2147483647 to 2147483647 (upper 4 digits including “-“)
−
−
−
d026
User monitor 1
-2147483647 to 2147483647 (upper 4 digits including “-“)
−
−
−
d027
User monitor 2
-2147483647 to 2147483647 (upper 4 digits including “-“)
−
−
−
4-5
d028
Pulse counter
0 to 2147483647 (upper 4 digits)
−
−
−
4-5
d029
Position setting monitor
-1073741823 to 1073741823 (upper 4 digits including “-“)
−
−
−
4-5
d030
Position feedback monitor
-1073741823 to 1073741823 (upper 4 digits including “-“)
−
−
−
4-5
d080
Trip Counter
0. to 9999., 1000 to 6553 (10000 to 65530) (times)
−
−
−
4-5
d081
Trip monitoring 1
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
−
−
−
d082
Trip monitoring 2
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
−
−
−
d083
Trip monitoring 3
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
−
−
−
d084
Trip monitoring 4
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
−
−
−
d085
Trip monitoring 5
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
−
−
−
d086
Trip monitoring 6
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
−
−
−
4-6
d090
Programming error monitoring
Warning code
−
−
−
4-6
d102
DC voltage monitoring
0.0 to 999.9 (V)
−
−
−
4-6
d103
BRD load factor monitoring
0.0 to 100.0 (%)
−
−
−
4-6
d104
Electronic thermal overload monitoring
0.0 to 100.0 (%)
−
−
−
4-6
8.3 Function Mode
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
F001
Output frequency setting
0.0, "start frequency" to "maximum frequency" (or maximum frequency, 2nd/3rd
motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.00
{
{
4-7
F002
Acceleration (1) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F202
Acceleration (1) time setting, 2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F302
Acceleration (1) time setting, 3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F003
Deceleration (1) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F203
Deceleration time setting, 2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F303
Deceleration time setting, 3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F004
Keypad Run key routing
00 (forward rotation), 01 (reverse rotation)
00
¯
¯
4-7
Содержание SJ700B SERIES
Страница 15: ...Contents xiii Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 45: ......
Страница 59: ......
Страница 223: ......
Страница 237: ......
Страница 245: ......
Страница 250: ...Chapter 7 Specifications 7 5 SJ700B 185 to 300HFF SJ700B 370HFF 5 Cable hole φ25 3 Cable hole 42 x 42 5 ...
Страница 251: ...Chapter 7 Specifications 7 6 SJ700B 450 to 550HFF 5 Cable hole φ41 ...
Страница 253: ......