Chapter 8 List of Data Settings
8 - 6
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
b001
Selection of restart mode
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03 (tripping
after deceleration and stopping with matching frequency), 04 (restarting with active
matching frequency)
00
¯
{
b002
Allowable under-voltage power failure
time
0.3 to 25.0 (s)
1.0
¯
{
b003
Retry wait time before motor restart
0.3 to 100.0 (s)
1.0
¯
{
b004
Instantaneous power
failure/under-voltage trip alarm enable
00 (disabling), 01 (enabling), 02 (disabling during stopping and decelerating to stop)
00
¯
{
b005
Number of restarts on power
failure/under-voltage trip events
00 (16 times), 01 (unlimited)
00
¯
{
4-33
b006
Phase loss detection enable
00 (disabling), 01 (enabling)
00
¯
{
4-36
b007
Restart frequency threshold
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
b008
Selection of retry after tripping
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03 (tripping
after deceleration and stopping with matching frequency), 04 (restarting with active
matching frequency)
00
¯
{
b009
Selection of retry after undervoltage
00 (16 times), 01 (unlimited)
00
¯
{
b010
Selection of retry count after
overvoltage or overcurrent
1 to 3 (times)
3
¯
{
Restar
t a
ft
e
r insta
n
taneo
us power
f
a
ilur
e
o
r tr
ipping
b011
Retry wait time after tripping
0.3 to 100.0 (s)
1.0
¯
{
4-33
b012
Electronic thermal setting (calculated
within the inverter from current output)
0.20 x "rated current" to 1.00 x "rated current" (A)
Rated current
of inverter
¯
{
b212
Electronic thermal setting (calculated
within the inverter from current output),
2nd motor
0.20 x "rated current" to 1.00 x "rated current" (A)
Rated current
of inverter
¯
{
b312
Electronic thermal setting (calculated
within the inverter from current output),
3rd motor
0.20 x "rated current" to 1.00 x "rated current" (A)
Rated current
of inverter
¯
{
b013
Electronic thermal characteristic
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
01
¯
{
b213
Electronic thermal characteristic, 2nd
motor
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
01
¯
{
b313
Electronic thermal characteristic, 3rd
motor
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
01
¯
{
4-37
b015
Free setting, electronic thermal
frequency (1)
0. to 400. (Hz)
0.
¯
{
b016
Free setting, electronic thermal current
(1)
0.0 to rated current (A)
0.0
¯
{
b017
Free setting, electronic thermal
frequency (2)
0. to 400. (Hz)
0.
¯
{
b018
Free setting, electronic thermal current
(2)
0.0 to rated current (A)
0.0
¯
{
b019
Free setting, electronic thermal
frequency (3)
0. to 400. (Hz)
0.
¯
{
Elect
ronic t
her
m
a
l
funct
ion
b020
Free setting, electronic thermal current
(3)
0.0 to rated current (A)
0.0
¯
{
4-38
b021
Overload restriction operation mode
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling during
constant speed), 03 (enabling during acceleration and deceleration (increasing the
speed during regeneration))
01
¯
{
b022
Overload restriction setting
0.20 x "rated current" to 1.50 x "rated current" (A)
Rated
current of
inverter x
1.20
¯
{
b023
Deceleration rate at overload
restriction
0.10 to 30.00 (s)
1.00
¯
{
b024
Overload restriction operation mode
(2)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling during
constant speed), 03 (enabling during acceleration and deceleration (increasing the
speed during regeneration))
01
¯
{
b025
Overload restriction setting (2)
0.20 x "rated current" to 1.50 x "rated current" (A)
Rated
current of
inverter x
1.20
¯
{
b026
Deceleration rate at overload restriction
(2)
0.10 to 30.00 (s)
1.00
¯
{
4-39
b027
Overcurrent suppression enable
00 (disabling), 01 (enabling)
01
¯
{
4-40
b028
Active frequency matching, scan start
frequency
0.20 x "rated current" to 1.50 x "rated current" (A)
Rated current
of inverter
¯
{
b029
Active frequency matching, scan-time
constant
0.10 to 30.00 (s)
0.50
¯
{
O
v
er
load
r
e
s
tr
ic
tion and
over
cur
rent r
e
str
a
int
b030
Active frequency matching, restart
frequency select
00 (frequency at the last shutoff), 01 (maximum frequency), 02 (set frequency)
00
¯
{
4-33
Soft
wa
re
lock
b031
Software lock mode selection
00 (disabling change of data other than "b031" when SFT is on), 01 (disabling change
of data other than "b031" and frequency settings when SFT is on), 02 (disabling
change of data other than "b031"), 03 (disabling change of data other than "b031" and
frequency settings), 10 (enabling data changes during operation)
01
¯
{
4-51
Содержание SJ700B SERIES
Страница 15: ...Contents xiii Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 45: ......
Страница 59: ......
Страница 223: ......
Страница 237: ......
Страница 245: ......
Страница 250: ...Chapter 7 Specifications 7 5 SJ700B 185 to 300HFF SJ700B 370HFF 5 Cable hole φ25 3 Cable hole 42 x 42 5 ...
Страница 251: ...Chapter 7 Specifications 7 6 SJ700B 450 to 550HFF 5 Cable hole φ41 ...
Страница 253: ......