Chapter 3 Operation
3 - 4
3.2.2 Code display system and key operations
This section describes typical examples of digital operator operation (in basic and full display modes) and
an example of special digital operator operation in extended function mode U.
The initial display on the monitor screen after power-on depends on the setting of function "b038". For
details, see Section 4.2.81, "Initial-screen selection," (on page 4-78).
When the setting of function "b038" is "01" (factory setting), the monitor initially shows as
the setting of function "d001" (output frequency monitoring). Pressing the key in this status
changes the display to .
Note: The display contents on the monitor depend on the settings of functions "b037" (function code
display restriction), "b038" (initial-screen selection), and "b039" (automatic setting of user
parameters). For details, see Sections 4.2.80, "Function code display restriction," (on page 4-76),
4.2.81, "Initial-screen selection," (on page 4-78), and 4.2.82, "Automatic user-parameter setting," (on
page 4-79).
Item Function
code
Data
Description
00 Full
display
01 Function-specific
display
02 User
setting
03
Data comparison display
Function code display
restriction
b037
04
Basic display (factory setting)
00
Screen displayed when the [STR] key was pressed last
(same as the operation on the SJ300 series)
01
d001 (output frequency monitoring)
02
d002 (output current monitoring)
03
d003 (rotation direction minitoring)
04
d007 (Scaled output frequency monitoring)
Initial-screen selection
(Initial display at
power-on)
b038
(*1)
05
F001 (output frequency setting)
00 Disable
Selection of automatic
user-parameter settings
b039
(*1)
01 Enable
*1 Not displayed with the factory setting
*
The following procedure enables you to turn the monitor display back to or (*1)
regardless of the current display mode:
- Hold down the key for 3 seconds or more. The monitor shows and (*1)
alternately.
During this status, press the key. The monitor will show only or (*1),
which is shown when the is pressed.
*1 The monitor shows only when the motor driven by the inverter is stopped. While the
motor is running, the monitor shows an output frequency.
FUNC
FUNC
FUNC
FUNC
Содержание SJ700B SERIES
Страница 15: ...Contents xiii Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 45: ......
Страница 59: ......
Страница 223: ......
Страница 237: ......
Страница 245: ......
Страница 250: ...Chapter 7 Specifications 7 5 SJ700B 185 to 300HFF SJ700B 370HFF 5 Cable hole φ25 3 Cable hole 42 x 42 5 ...
Страница 251: ...Chapter 7 Specifications 7 6 SJ700B 450 to 550HFF 5 Cable hole φ41 ...
Страница 253: ......