Inverter Specifications
Getting Star
ted
1–10
General Specifications
The following table applies to all L200
2
inverters.
Item
General Specifications
Protective housing *1
IP20
Control method
Sinusoidal Pulse Width Modulation (PWM) control
Carrier frequency
2kHz to 14kHz (default setting: 5kHz)
Output frequency range *4
0.5 to 400 Hz
Frequency accuracy
Digital command: 0.01% of the maximum frequency
Analog command: 0.1% of the maximum frequency (25
°
C ± 10
°
C)
Frequency setting resolution
Digital: 0.1 Hz; Analog: max. frequency/1000
Volt./Freq. characteristic
V/f optionally variable, V/f control (constant torque, reduced torque)
Overload capacity
150% of rated current for 1 minute
Acceleration/deceleration time
0.01 to 3000 seconds, linear and S-curve accel/decel, second
accel/decel setting available
Input
signal
Freq.
setting
Operator panel
Up and Down keys / Value settings
Potentiometer
Analog setting
External signal
*9
0 to 10 VDC (input impedance 10k Ohms), 4 to 20 mA (input
impedance 250 Ohms), Potentiometer (1k to 2k Ohms, 2W)
FWD/
REV
Run
Operator panel
Run/Stop (Forward/Reverse run change by command)
External signal
Forward run/stop, Reverse run/stop
Intelligent input
terminal
FW (forward run command), RV (reverse run command), CF1~CF4
(multi-stage speed setting), JG (jog command), DB (external
braking), SET (set second motor), 2CH (2-stage accel./decel.
command), FRS (free run stop command), EXT (external trip), USP
(startup function), SFT (soft lock), AT (analog current input select
signal), RS (reset), PTC (thermistor thermal protection), STA (start),
STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID
reset), UP (remote control up function), DWN (remote control down
function), UDC (remote control data clearing), OPE (operator
control), ADD (ADD frequency enable), F-TM (force terminal
mode), RDY (quick start enable)
Output
signal
Intelligent output
terminal
RUN (run status signal), FA1,2 (frequency arrival signal), OL
(overload advance notice signal), OD (PID error deviation signal),
AL (alarm signal), Dc (analog input disconnect detect), FBV (PID
two-stage control output), NDc (network detection signal), LOG
(logic output), OPDc (option card detection signal)
Frequency monitor
PWM output; Select analog output frequency monitor, analog output
current monitor or digital output frequency monitor
Alarm output contact
ON for inverter alarm (1C contacts, both normally open or closed
avail.)
Содержание L200-002NFE2
Страница 2: ......
Страница 46: ......
Страница 80: ......
Страница 204: ......
Страница 205: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 212: ......
Страница 229: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 280: ......
Страница 281: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 293: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 D ...
Страница 297: ...L2002 Inverter Appendix D D 5 L1 L2 L3 PE L2002 inverter with book type filter M 3 ...