Note 1:
When using the Multi-speed Select settings CF1 to CF4, do not display
parameter F001 or change the value of F001 while the inverter is in Run Mode
(motor running). If it is necessary to check the value of F001 during Run
Mode, please monitor D001 instead of F001.
53
S-ST
Special-Set (select)
2nd Motor Data
ON
The inverter uses 2nd motor parameters for
generating frequency output to motor. The selec-
tion of 1st or 2nd motor is available during Stop
Mode or Run Mode.
OFF
The inverter uses 1st (main) motor parameters
for generating frequency output to motor
255
—
Not selected
ON
(input ignored)
OFF
(input ignored)