Introduction
Appendix C
C–2
Introduction
This appendix lists the user-programmable parameters for the L200
2
series inverters and
the default values for European and U.S. product types. The right-most column of the
tables is blank, so you can record values you have changed from the default. This
involves just a few parameters for most applications. This appendix presents the parame-
ters in a format oriented toward the keypad on the inverter.
Parameter Settings for Keypad Entry
L200
2
series inverters provide many functions and parameters that can be configured by
the user. We recommend that you record all parameters that have been edited, in order to
help in troubleshooting or recovery from a loss of parameter data.
Main Profile Parameters
}
This information is printed
on the specification label
located on the right side of
the inverter.
L200
2
Inverter model
MFG. No.
“F” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
–FE(F)
(Europe)
–FU
(USA)
F001
Output frequency setting
0.0
0.0
F002
Acceleration (1) time setting
10.0
10.0
F202
Acceleration (1) time setting, 2nd
motor
10.0
10.0
F003
Deceleration (1) time setting
10.0
10.0
F203
Deceleration (1) time setting, 2nd
motor
10.0
10.0
F004
Keypad Run key routing
00
00
Содержание L200-002NFE2
Страница 2: ......
Страница 46: ......
Страница 80: ......
Страница 204: ......
Страница 205: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 212: ......
Страница 229: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 280: ......
Страница 281: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 293: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 D ...
Страница 297: ...L2002 Inverter Appendix D D 5 L1 L2 L3 PE L2002 inverter with book type filter M 3 ...