51
2.7 Environmental requirements
(1) Dust
Cooling fans are embedded in the Device. Do not install the Device in a humid or dusty
place. The dust conditions of the Device are as follows:
Airborne dust concentration: 0.15 mg/m
3
or less (according to JIS Z 8813 Measuring
Methods for Suspended Particulate Matter Concentration in Air - General
Requirements)
NOTE
Generally, areas around printers or lots of people contain a lot of toner or dust. Do not install
a device in such places.
(2) Corrosive and flammable gases
Install a Device somewhere without corrosive or flammable gases. If the Device is installed
where it is exposed to corrosive gases, the Device will deteriorate and become unreliable.
(3) Floor surface material
The Device can be installed in an ordinary office room. However, it is recommended that
the floor surface be the following:
Fire resistance
Dust-free
(4) Direct sunlight
Do not expose the device to direct sunlight.
(5) Water
Keep the device away from spilt water when cleaning the floor.
(6) Electromagnetic interference
Please note that when using high-frequency devices near the Device, waves emitted by
such devices might interfere with normal operation of the Device.
The Device generates weak high-frequency radio waves that might affect indoor antennas
for television, radio, and transceivers within 30 m of the Device.
(7) Protecting cables
Route the cables through ducts or cover them for protection.
If cables are unprotected, mice or other animals might bite or chew them, leading to a cable
disconnection.
Optical fiber requires special handling; lay the cables with a bend radius of more than
100 mm along the major axis and 50 mm along the minor axis, and protect them with metal
covers.
Regarding optical fiber cables containing the required number of cores, ensure that there is
a protective structure against repeated mechanical stress due to bending, stretching,
Содержание GX1000-SMC013X
Страница 94: ...94 5 Configuration Guide 5 1 Base Software Configuration Guide ...
Страница 105: ...105 7 Access Lists 7 1 Access lists ...
Страница 153: ...153 8 Policy Based Switching 8 1 Policy based switching ...
Страница 165: ...165 9 Policy Based Routing 9 1 Policy based routing ...
Страница 177: ...177 Figure 10 1 Overview of mode transitions ...
Страница 188: ...188 14 Configuration Command Reference 14 1 Reading the configuration command reference 14 2 SNMP 14 3 SP functionality ...
Страница 208: ...208 16 Message and Log Reference 16 1 Operation messages and logs 16 2 Device Failure and Event Information ...
Страница 213: ...213 17 MIB Reference 17 1 Private MIBs 17 2 Supported MIB Traps ...
Страница 224: ...224 19 1 Starting the device For details see 5 1 Login procedures in the Base Software Configuration Guide ...
Страница 229: ...229 H W BOOT 11 44 MISC 1 0 SPCT 0 34 10 The updating of the SP files is finished ...
Страница 448: ...448 27 Notes This chapter provides notes on using the WAN acceleration functionality 27 1 Note ...
Страница 451: ...451 28 Additional Information ...