116
layer2-forwarding
Specifies the forwarding type to be detected in flow detection.
layer2-forwarding
detects IP packets forwarded on Layer 2 in flow detection.
This parameter has an effect only when it is applied to an Ethernet interface.
1.
Default value when this parameter is omitted:
This parameter cannot be omitted.
2.
Range of values:
None
layer2-and-layer3-forwarding
Specifies the forwarding type to be detected in flow detection.
layer2-and-layer3-forwarding
detects packets forwarded on Layer 2 and Layer
3 in flow detection.
This parameter has an effect only when it is applied to a VLAN interface.
1.
Default value when this parameter is omitted:
This parameter cannot be omitted.
2.
Range of values:
None
Default behavior
None
Impact on communication
When an access list with at least one entry is applied to an interface, IP packets received at
the interface are discarded temporarily until the entry is applied to the interface.
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1.
On an Ethernet interface, you can set one Advance access list for Inbound and one
Advance access list for Outbound.
If an Advance access list has already been set, first remove it and then set it again.
2.
If you specify a non-existent Advance filter, this will be ignored. The identifier of the
Advance filter is registered.
3.
You can set an Advance access list if the flow distribution pattern is
default
standard-advance
,
default extended-advance
,
filter-only
extended-advance
,
filter extended-advance
, or
qos extended-advance
.
4.
If
mac-ip
is specified for the flow detection condition type and the
own-address
or
own
parameter is specified in the flow detection condition, you can set an Advance
access list if an IPv4 address is set for the target interface.
5.
If
mac-ipv6
is specified for the flow detection condition type and the
own-address
or
own
parameter is specified in the flow detection condition, you can set an Advance
access list if only one IPv6 global address is set for the target interface.
6.
If an Advance access list is to be applied to an Ethernet interface and a VLAN
parameter is set in the flow detection condition, you can set the list if all VLAN IDs
corresponding to the VLAN parameters are included in the settings of the Ethernet
interface.
Содержание GX1000-SMC013X
Страница 94: ...94 5 Configuration Guide 5 1 Base Software Configuration Guide ...
Страница 105: ...105 7 Access Lists 7 1 Access lists ...
Страница 153: ...153 8 Policy Based Switching 8 1 Policy based switching ...
Страница 165: ...165 9 Policy Based Routing 9 1 Policy based routing ...
Страница 177: ...177 Figure 10 1 Overview of mode transitions ...
Страница 188: ...188 14 Configuration Command Reference 14 1 Reading the configuration command reference 14 2 SNMP 14 3 SP functionality ...
Страница 208: ...208 16 Message and Log Reference 16 1 Operation messages and logs 16 2 Device Failure and Event Information ...
Страница 213: ...213 17 MIB Reference 17 1 Private MIBs 17 2 Supported MIB Traps ...
Страница 224: ...224 19 1 Starting the device For details see 5 1 Login procedures in the Base Software Configuration Guide ...
Страница 229: ...229 H W BOOT 11 44 MISC 1 0 SPCT 0 34 10 The updating of the SP files is finished ...
Страница 448: ...448 27 Notes This chapter provides notes on using the WAN acceleration functionality 27 1 Note ...
Страница 451: ...451 28 Additional Information ...