218
18.1 Troubleshooting functional failures during operation
This chapter describes what actions to take when a problem occurs, such as when a
Device does not operate correctly or cannot communicate.
18.1.1 SP problems
(1) The SP service is not ready
Execute the
show nif
or
show interfaces
operation command to check the operating
status of the SP firmware. If the status is out of service, take action according to the
following table.
Table 18-1 Checking the operating status of SP firmware and taking the action
No.
Operating
status of SP
firmware
Cause
Action
1
Booting
The SP is being initialized.
Wait until SP initialization has finished.
2
Pre-service
The SP service is starting up.
Wait until the SP service has started.
3
Closing
The SP is being blocked by the
inactivate
command.
Wait until the SP is no longer blocked.
After the SP is available again, execute the
active
command to re-activate the SP.
4
Closed
The SP is blocked by the
inactivate
command.
Execute the
activate
command to activate the SP.
5
Out of
Service
The SP is out of service.
Perform the following procedure:
1. Execute the
show logging
command to check the
log details for the SP.
2. See 16.2 Device Failure and Event Information and
take action described in Action.
6
Fault
The SP caused the failure.
Same as the above.
Содержание GX1000-SMC013X
Страница 94: ...94 5 Configuration Guide 5 1 Base Software Configuration Guide ...
Страница 105: ...105 7 Access Lists 7 1 Access lists ...
Страница 153: ...153 8 Policy Based Switching 8 1 Policy based switching ...
Страница 165: ...165 9 Policy Based Routing 9 1 Policy based routing ...
Страница 177: ...177 Figure 10 1 Overview of mode transitions ...
Страница 188: ...188 14 Configuration Command Reference 14 1 Reading the configuration command reference 14 2 SNMP 14 3 SP functionality ...
Страница 208: ...208 16 Message and Log Reference 16 1 Operation messages and logs 16 2 Device Failure and Event Information ...
Страница 213: ...213 17 MIB Reference 17 1 Private MIBs 17 2 Supported MIB Traps ...
Страница 224: ...224 19 1 Starting the device For details see 5 1 Login procedures in the Base Software Configuration Guide ...
Страница 229: ...229 H W BOOT 11 44 MISC 1 0 SPCT 0 34 10 The updating of the SP files is finished ...
Страница 448: ...448 27 Notes This chapter provides notes on using the WAN acceleration functionality 27 1 Note ...
Страница 451: ...451 28 Additional Information ...