Commissioning
48/90
Ø
Under
Snapshot behaviour in autonomous mode
, set the maximum
number of snapshots to be stored on the USB memory device.
·
If "0" is specified, snapshots are saved until the USB memory is full.
After that, no more snapshots will be saved.
·
If a number greater than "0" is specified, the USB memory contains this
maximum number of snapshots. When the maximum number is
reached, the oldest snapshots are automatically deleted. Thus, the USB
memory device contains only the most recent snapshot events. Note
that if there is not enough space left on the USB memory device, no
more snapshots will be taken.
Ø
Click
Apply changes and restart device
.
ð
The set value is stored in the analyzer device NANL-B500G-RE and
defines the maximum number of snapshots that are stored on the USB
memory device in the autonomous mode in snapshot mode.
ð
The device is restarted.
7.4.7
Starting or stopping NANL-B500G-RE in the Autonomous operating
mode
Starting: Press briefly the red REC button on the device front side.
Stopping: Press and hold the red REC button on the device front side for at
least 1 second.
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public
© Hilscher 2007-2019