Getting started
33/90
Static IP address or DHCP client operation
To use
Static IP address
or
DHCP client mode
, you can configure your
netANALYZER portable device NANL-B500G-RE using the
Ethernet
Device Configuration
program. In
Ethernet Device Configuration
, to find
the NANL-B500G-RE device, you must enable the
NetIdentV2
protocol.
For details refer to the
operating instruction manual
Address setting for Ethernet capable Hilscher
devices
. You find this manual on the product DVD under
Documentation
.
Note:
In case of problems due to incorrect settings of the IP address (e. g.
device is not accessible), restart your device. While turning on your
device press the REC button for about 1 minute. Then the default
setting for the IP address of your device (DHCP server mode) is
restored.
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public