Connectors and interfaces
81/90
11.3 External IO interface
The external IO interface has 4 digital inputs or outputs, the GPIOs 0 to 3.
Each
can be configured as input or output.
Device Destruction!
Ø
At the I/O signal pins of the External IO interface use exclusively 3.3 V
or 24 V signaling voltage. Higher signaling voltages lead to severe
damage to the NANL-B500G-RE device!
Ø
To operate the NANL-B500G-RE device, at the I/O signal pins of the
external I/O interface, take a maximum of 1 mA (at 3.3V) or 600 mA (at
24V) current. Otherwise the netX chip and other components may be
damaged.
Male connector external IO interface with GPIOs 0 to 3:
Figure 29: Male Connector external IO interface
Pin
Signal
Pin
Signal
2
GND
1
3
4
GND
3
2
6
GND
5
1
8
GND
7
0
Table 23: Pin out external IO interface
11.3.1
Connection cable for external IO interface
To access the digital signals of the GPIOs 0 to 3 of the external IO
interface, you must use a cable that complies with the following
requirements.
Parameters
Requirement
Min. conductor cross
section
0,2 mm
2
Max. conductor cross
section
1 mm
2
Max. cable length
3 m
Shielding
Shielded cables
Table 24: Requirements for the connection cable for external IO interface
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public
© Hilscher 2007-2019