Getting started
27/90
Note
Description
ext4 file system support on
USB memory device
Files written to a FAT32-formatted USB memory device are not power fail-safe. The user
can use the ext4 file system on the USB memory device for autonomous operation mode to
ensure failsafe recovery, even if the power supply of the netANALYZER is interrupted
during write access to the USB memory device.
·
In order to format the USB memory device with the ext4 file system, the user must use a
PC with a LINUX operating system or a corresponding additional file system driver for
Windows.
·
In order to read the files from the USB memory device with the ext4 file system, the user
must use a PC with a LINUX operating system or a corresponding additional file system
driver for Windows.
Table 11: Notes about installation and operation
5.2
Overview installation
No
Step
Description
Detailed information, see chapter /
section
1
Software installation
1.1
Requirements
- NET Framework
- Install Wireshark
- Windows
®
10 Server is not supported.
1.2
Install
netANALYZER
Scope
software
- Download the product DVD as a ZIP file to
the local hard disk of your PC
- Unzip the ZIP file
- Double-click the
*.exe
file in the root directory
of the DVD to open the autostart menu.
- Install netANALYZER Scope software.
If Wireshark live records are desired, install
WinPcap driver for netANALYZER.
User manual software installation for
netANALYZER
2
Hardware installation
2.1
Safety messages
Adhere
- to the
Property damage messages
given in
this manual.
2.2
NANL-B500G-RE
Connect the analyzer device NANL-B500G-RE
to the RJ45 Ethernet socket (1 Gb/s) at the
separate network card with in the PC.
Interactive operating mode, connection
to PC
2.3
Inserting Hardware in the
communication link
Note!
The RJ45 connector may only be used
for LAN, not for telecommunications
connections.
Important!
As long as the analyzer device
NANL-B500G-RE works in DHCP server
mode, the analyzer device must not be
inserted directly into a company network via a
switch or hub in which other devices are also
located.
Insert the analyzer device NANL-B500G-RE
into the communication path to be analyzed.
Inserting netANALYZER hardware into
the communication Link
Table 12: Overview installation
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public
© Hilscher 2007-2019