Commissioning
52/90
Ê
Each time a trigger criterion is met, a snapshot is stored to the USB
memory device.
Note:
The internal memory of the analyzer device NANL-B500G-RE can
buffer a maximum of 300 MB of Ethernet frame data, so that this
maximum past events depth is available for snapshots. Depending
on the network load, this results in the maximum detectable time
period.
Ø
To stop capturing, press the red REC button on the front side of the
device for at least 1 second.
Note:
After stopping capturing, the NANL-B500G-RE analyzer device
stores the previously captured data on the USB memory device for
a few seconds. Wait until the STA0 LED changes from red to
orange, before disconnecting the USB memory device. Otherwise,
data may be lost, i.e. the captured pcap files may be incomplete.
Ê
The number of stored snapshots depends on the maximum number
specified (see section
Set maximum number of snapshots for
page 46]).
Ø
Remove the USB memory device from the USB socket on the reverse
side of the device and connect it to a PC.
Ø
The generated .nsprj files are located in the saved_snapshots directory.
They can be opened in netANALYZER Scope.
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public