B. Wiring Requirements
IntelliFire Touch
®
Ignition System Wiring
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.3, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Touch
control valve which operates on a 6 volt/1.5 AMP system.
Figure 8.3 Intellifire Touch Wiring Diagram
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
FLAME
SENSE
IGNITER
TO JUNCTION BOX 110-120 VAC
LED
CONTROL
RF MODULE
ORANGE
(PILOT)
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
WIRE ASSEMBLY
MODULE
RESET
SWITCH
RED
FRONT EMBER LIGHTING (X 3)
BLACK/RED
REAR ACCENT LIGHTING (X 2)
BLACK/RED
6V DC
BATTERY PACK
BLK
RED
(OPTIONAL)
JUMPER
WIRE
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
OPTIONAL HEAT-ZONE-GAS or HEAT-OUT-GAS KIT
Optional HEAT-ZONE-GAS kit shown wired
to IFT-ACM. Appliance must be re-paired if
adding a HEAT-ZONE-GAS or HEAT-OUT-GAS
to the IFT-ACM.
Wiring MUST be performed by a certified
electrician.
Thick line denotes wiring
supplied by electrician.
HEAT-OUT-GAS
WIRE PLUG ASSEMBLY
26D0619