Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual • 2461-980 Rev. Q • 11/20
34
A. Vent Collar Preparation
6
6
Appliance Preparation
SEAL CAP
SEAL CAP
GASKET
GASKET
Figure 6.2 Seal Cap and Gasket Location
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
NOTICE: This appliance is top vented ONLY.
1. Remove shrink wrap from appliance. Figure 6.1 shows
the shipping location of the seal cap and heat shields
(Section 6), splatter guard and finishing templates
(Section 10), and the logs and Teco-Sil (Section 11).
For TRUE-36G-IFT and TRUE-42G-IFT models, the
glass refractory is also shipped with the appliance. See
Figure 6.1.
Figure 6.1 Shipping Location of Components
SEAL CAP
SEAL CAP
LOGS
LOGS
SPLATTER GUARD
SPLATTER GUARD
FINISHING
FINISHING
TEMPLATES
TEMPLATES
HEADER HEAT SHIELDS
HEADER HEAT SHIELDS
(SHIPPED ON REAR SIDE OF APPLIANCE
(SHIPPED ON REAR SIDE OF APPLIANCE
TECO-SIL
TECO-SIL
GLASS REFRACTORY
GLASS REFRACTORY
TRUE-36G-IFT AND
TRUE-36G-IFT AND
TRUE-42G-IFT ONLY
TRUE-42G-IFT ONLY
HEADER HEAT SHIELD
HEADER HEAT SHIELD
AND FINISH TRIM
AND FINISH TRIM
TRUE-36G-IFT AND
TRUE-36G-IFT AND
TRUE-42G-IFT ONLY
TRUE-42G-IFT ONLY
2. Remove seal cap from top of appliance by removing
one screw, which is included, to prevent construction
material from getting into appliance. Remove seal cap
when pipe installation phase begins. See Figure 6.2.
3. Ensure gasket seal is in place prior to installing vent
pipe sections. Gasket is installed at the factory.
NOTE:
Header heat shields and finish trim on TRUE-G
models are attached to appliance on the rear corner and
must be removed using a 1/4 inch nut driver. See Figure
6.3.