29
Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual • 2461-980 Rev. Q • 11/20
Three Elbows
TRUE-36 (NG/P), TRUE-42 (NG/P), TRUE-50 (NG/P)
V
1
Minimum
H
1
H
2
V
2
H
TOTAL
Max.
2 ft
610 mm
*
*
**
7 in
178 mm
3 ft
914 mm
*
*
**
2 ft
610 mm
4 ft
1.2 m
*
*
**
4 ft
1.2 m
5 ft
1.5 m
*
*
**
8 ft
2.4 m
6 ft
1.8 m
*
*
**
12 ft
3.7 m
7 ft
2.1 m
*
*
**
14 ft
4.3 m
10 ft
3.0 m
*
*
**
20 ft
6.1 m
*H
1
and H
2
has no specific restrictions EXCEPT,
after V
1
= 6 ft, then H
TOTAL
Max = 2 x V
1
**V
TOTAL
+
H
TOTAL
= 50 ft (15.2 m) Max.
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
Top Vent - Vertical Termination - (continued)
WARNING! Risk of Fire!
• TRUE-36(NG/P), TRUE-42(NG/P) and TRUE-50 (NG/P)
models require a minimum of 24 inches of vertical venting
before attaching any elbow to the appliance.
DO NOT attach elbow directly to the appliance.
Figure 4.15