63
NTT 240/460
Operation mode
Installation and user guide
Rev: 4.0
2.
Digital Input:
drive digital input setting in I/O operation mode. For any other information about digital input
functions, please see
“6.08.1 Digital I/O functions” pag. 85.
•
Filter Input
: input 1
ST
order filter parameters, in ms unit.
3.
Factors:
multiplier factors associated with input reference in order to modify scale resolution. Please see
.
4.
Position Setting:
maximum admitted position error and maximum admitted recovery time setting; beyond
these values drive provides an error/alarm condition.
5.
Position
: setting for all parameters related to desired position control between single target positioner,
analog positioner, cyclic/acyclic table selection or via digital input or via input start up to 64 target. For
further information, please see
“6.09 Drive references” pag. 87
“6.15.5 Position control: positioner mode”
.
•
Pos Parameter:
profile setting and position procedure setting, software positive and negative limits and
Homing offset.
•
Position Jog:
JOG setting.
•
Home Position:
HOMING procedures and parameters. For further information, please see Modbus user
guide.
•
Pos. - Input X:
index stop, at relative position, when event happens on INPUT X of drive I/O connector.
6.
Main Speed:
speed control and main speed reference setting between analog, inside, frequency or Tab-
selection. For further information please see
“6.09 Drive references” pag. 87
and
“6.15.3 Sensorless speed control” pag. 102
•
Aux Speed
: auxiliary speed reference setting between analog, inside or torque limit.
•
Ramps
: acceleration and deceleration ramp managment; linear ramp or S ramp (JERK parameter).
7.
GearBox:
gearbox axis rate management and engage and disengage settings; input type can be selected
between
CHA/B
,
CW/CCW, Pulse/Direction
input reference. For turther information please see
and
“6.15.4 Position control: electronic gearbox mode” pag. 103
•
Engaging:
engaging phase parameter set
•
Disengaging:
disengaging phase parameter set
•
Home position:
HOMING procedures and parameters. For further information, please see Modbus user
guide.
•
Gearbox JOG:
JOG setting.
8.
Torque:
torque control setting and input reference setting between analog and inside. For further information
“6.09 Drive references” pag. 87
and
“6.15.1 Torque control” pag. 100
.
9.
Electronic Cam:
Cam table and all parameter setting. For further information, please see
“6.15.6 Position control: electronic cam mode” pag. 105
.
•
Sync/Shift:
isync parameter set and master/slave position shift setting.
•
Data Engaging:
engaging phase parameter set
•
Data Disengaging:
disengaging phase parameter set
•
Home position:
HOMING procedures and parameters. For further information, please see Modbus user
guide.
•
Cam JOG:
JOG setting.
10.
Press:
pressure reference accuracy setting and fullscale setting for speed and pressure reference and for
pressure transducer. For further information please see
“6.09 Drive references” pag. 87
and
•
Setting:
safety pressure threshold setting, beyond which the drive introduces set speed limit. Speed
variation is managed with ramp.
•
Limit:
current and negative speed limit setting.
•
Alarm mode:
overpressure and underpressure threshold setting and enabling.
•
Pressure Reg.:
pressure ring regulators setting.
•
Ramps:
pressure and speed ramps setting and enabling.
•
Output:
analog output fullscale setting and output setting for pressure reached condition related to
pressure and time window parameter.
Содержание NTT 240