5.10.4 Cable per J7-8-9
Wiring connections and pins numbering for J4 connector is shown below, according to previous table related to
J8 connector (J7 and J9 connector cable are similar, but with different pin number):
11
20
10
1
11
20
10
1
!
Please ensure that insertion hook of connector is
facing correctly.
!
NOTES:
•
0L and 0S common ground are equipotential and maximum permitted voltage against Power Earth
(PE) is 50V.
•
Maximum permitted voltage for 0V, 0V_I/O against Power Earth (PE) is 100V.
•
Do not use +24V (pin 2 of J8) to directly engage motor brake.
•
Single ended PNP connection for analog references is to connect negative pins
(pin 2-4-6 of J9)) to
0S ground (pin 8 of J9) and to connect signal to positive pins (pin1-3-5 of J9); this connection type is
usefull if the external controller device has not differential analog output, but ±10V single ended only,
and if this analog input is used as digital input.
•
Keep I/O cables far from supply and feedback cables.
•
To ensure a correct electric wiring, and for electric safety, strip the wire up to 6-8mm, or use an
appropriate cap.
•
For frequency main reference input and analog input, it’s mandatory to use shielded cable.
Содержание NTT 240