79
NTT 240/460
Operation mode
Installation and user guide
Rev: 4.0
L1
Description
L2
Description
L3
Description
PAR.
Description
Value
Type
F
PRESSURE
CONTROL
(continue)
F4
ANALOG OUTPUT MANAGEMENT
F.4000
Pressure output
0 ÷ 1000 bar
W
F.4001
Speed output
1 ÷ 9999 RPM
W
DIGITAL OUTPUT MANAGEMENT
F.4002
Pressure error
1 ÷ 1000 bar
W
F.4003
Threshold time
1 ÷ 60000 ms
W
F5
ALARM MODE
THRESHOLD MANAGEMENT
F.5000
Overpressure
1 ÷ 1000 bar
W
F.5001
Time for F.5000
1 ÷ 60000 ms
W
F.5002
Enable F.5000
ON/OFF
S
F.5003
Under pressure
1 ÷ 1000 bar
W
F.5004
Time for F.5003
1 ÷ 60000 s
W
F.5005
Enable F.5003
ON/OFF
S
F6
PRESSURE PID REGULATORS AND
EXPONENTIAL MULTIPLYER COEFFICIENTS
F.6000
KP Pressure
1 ÷ 32767
W
F.6001
Exponential for KP
-16 ÷ 16
W
F.6002
KI Pressure
1 ÷ 32767
W
F.6003
Exponential for KI
-16 ÷ 16
W
F.6004
KD Pressure
1 ÷ 32767
W
F.6005
Exponential for KD
-16 ÷ 16
W
F7
PRESSURE RAMPS ON REFERENCE
F.7000
Acceleration
1 ÷ 60000 bar/s
W
F.7001
Deceleration
1 ÷ 60000 bar/s
W
F.7002
Jerk
0 ÷ 10000 ms
W
F.7003
Ramp enable
ON/OFF
S
SPEED RAMPS ON REFERENCE
F.7004
Acceleration
1 ÷ 60000 RPM/s
W
F.7005
Deceleration
1 ÷ 60000 RPM/s
W
F.7006
Ramp enable
ON/OFF
S
S
ADVANCED
SETUP
S1
PID
REGULATORS
S10 PID SPEED
S.1000
KP speed
1 ÷ 65535
W
S.1001
KI speed
0 ÷ 65535
W
S.1002
KD speed
0 ÷ 65535
W
S11 PID CORRENTE
S.1100
KP current
1 ÷ 65535
W
S.1101
KI current
0 ÷ 65535
W
S.1102
KD current
0 ÷ 65535
W
S12
PID ASINCRONO
DI FLUSSO
S.1200
KP flux
0 ÷ 65535
W
S.1201
KI flux
0 ÷ 65535
W
S13
PID ASINCRONO
DEFLUSSAGGIO
S.1300
KP flux weakening
0 ÷ 65535
W
S.1301
KI flux weakening
0 ÷ 65535
W
S14 PID POSIZIONE
S.1400
KP posizione
0 ÷ 4000
W
S15
ERRORE DI
POSIZIONE
S.1500
Error threshold
0 ÷ 65535 cnts
W
S.1501
Threshold time
10 ÷ 10000 ms
W
S3
ENCODER RESOLUTION
and
ALARMS
S.3000
Encoder output res.
256-1024-4096-16384 ppr
S
S.3002
Reset alarms
command
ON/OFF
W
S.3003
Alarm list
Last 16 appeared alarms
R
S.3004
Firmware version
‘SFX.XX’ firmware version
R
S.3005
Feedback Reverse
ON/OFF
S
S.3006
Encoder output type
‘0 rIF’ frequency reference
‘1 SIM’ emulated enc. out
‘2 EnC’ motor encoder
S
S.3007
Enc. out. reverse
ON/OFF
S
S4
ALARM MODE
S.4002
STO alarm mode
‘oFF’ stored
‘on’ autoreset
W
S.4008
Check 24V for I/O
ON/OFF
W
Содержание NTT 240