32
Installation and user guide
Rev: 4.0
NTT 240/460
Wiring and connections
5.04 J3 connector: EC and PN option configuration
» EC configuration: Ethercat
FIELD BUS
OUT
IN
J3
FIELD BUS
OUT
IN
J3
FIELD BUS
J3
FIELD BUS
OUT
IN
J3
1
2
3
4
5
6
B
A
8
1
8
1
Act
Link/Act
Act
Run
Link/Act
Act
Link/Act
Act
Link/Act
Bus
Failure
B
A
1
8
1
8
B
A
8
1
8
1
Connector TYPE
Double RJ45: IN (A) and OUT (B) port with Link/Act and
fieldbus status led.
Utility
Fieldbus comunication protocol:
•
Ethercat CoE
, (Canopen® CiA 402 over Ethercat) with EC
option.
N° pins
and
LEDs
8 x 2
(Ethernet standard according to EN50173-1:2011).
4 x LED
link/activity and
1 x green LED
for fieldbus status.
» PN configuration: Profinet
FIELD BUS
OUT
IN
J3
FIELD BUS
OUT
IN
J3
FIELD BUS
J3
FIELD BUS
OUT
IN
J3
1
2
3
4
5
6
B
A
8
1
8
1
Act
Link/Act
Act
Run
Link/Act
Act
Link/Act
Act
Link/Act
Bus
Failure
B
A
1
8
1
8
B
A
8
1
8
1
Connector TYPE
Double RJ45: IN (A) and OUT (B) port with Link/Act and
fieldbus status led.
Utility
Fieldbus comunication protocol:
•
Profinet RT
, (Profidrive CA e CB) with PN option.
N° pins
and
LEDs
8 x 2
(Ethernet standard according to EN50173-1:2011).
4 x LED
link/activity and
1 x red LED
for fieldbus status.
PIN
J3 connector description - EC and PN Option
Cable
A1-B1
TD +
Transmit Data +
8
1
A2-B2
TD -
Transmit Data -
A3-B3
RD +
Receive Data +
A4-B4
-
A5-B5
-
A6-B6
RD -
Receive Data -
A7-B7
-
A8-B8
-
!
NOTES:
•
Monitored Fieldbus: for information, see
.
•
Keep comunication cables far from power and feedback cables.
•
It may be necessary to use a switch repeter for bus lenght grater than 1000m.
•
Use shielded patch cable (pin-to-pin) FTP 568 (B) Cat. 5 or better.
•
As to connect multiple drives, RJ45 needs a cascade connection, so the wiring between the drives
themselves must be pin-to-pin.
•
For information about cable, see
.
Содержание NTT 240