55
NTT 240/460
Operation mode
Installation and user guide
Rev: 4.0
6.03.2 Menu: ‘MOTOR DATA’ item and ‘FEEDBACK’ sub-menu
‘Motor Data’ item allows to enter parameters and permanent magnets motor type connected to drive:
1.
“PM rotary motor”
: brushless permanent magnet rotative motor.
2.
“PM linear motor”
: brushless permanent magnet linear motor.
3.
“Rotary, brushed DC motor”
: brushed permanent magnet DC motor.
4.
“Induction V/Hz”
: asynchronous motor (induction) with V/Hz control.
6.03.2.a
Brushless permanent magnet rotative motor
It’s necessary to set correctly:
•
Nominal Speed
•
Nominal Current
•
Peak Current
•
Motor Poles
: (up to 50poles).
•
I2T Time
: motor I2T, default set to 10s.
All feedback supported are suitable for this motor type.
Other choke parameters usefull for sensorless control.
6.03.2.b
Brushless permanent magnet linear motor
It’s necessary to set correctly:
•
Nominal Speed
•
Nominal Current
•
Peak Current
•
Pole Pitch
in mm.
•
I2T Time
: motor I2T, default set to 10s.
All feedback supported are suitable for this motor type.
Other choke parameters usefull for sensorless control.
6.03.2.c
Brushed permanent magnet DC motor
It’s necessary to set correctly:
•
Nominal Speed
•
Nominal Current
•
Peak Current
•
I2T Time
: motor I2T, default set to 10s.
All feedback supported are suitable for this motor type
with exception for sensorless control.
Содержание NTT 240
Страница 129: ......