77
NTT 240/460
Operation mode
Installation and user guide
Rev: 4.0
Menu P:
position control parameter setting
Menu F:
pressure control parameter setting
Menu S:
drive advanced setup parameters
Menu H:
drive reserved setup parameters (only for authorized personnel)
6.06.1 Keybord access parameters
Table below shows parameter access via keyboard (press ESC + ENTER at the same time).
L1
Description
L2
Description
L3
Description
PAR.
Description
Value
Type
d
BASIC
DISPLAY
PARAMETERS
d.0000
Drive status
‘EnA’ = Switch-ON
‘Run’ = Operation Enable
‘StoP’ = Switch-OFF
‘F XX’ or ‘FA XX’ = Fault XX
R
d.0001
Motor speed
-9999 ÷ 9999 RPM
R
d.0002
Provided current
-99.99 ÷ 99.99A o
-999.9 ÷ 999.9 A
R
d.0003
DCbus voltage
0 ÷ 1000V
R
d.0004
Drive temperature
0 ÷ 200.00 °C
R
d.0005
Position-rounds
-32767 ÷ 32767 cnts
R
d.0006
Position-offset
0 ÷ 65535 cnts
R
d.0007
H.P. freezing
0 ÷ 65535 cnts
R
d.0008
Drive current size
Drive current size
R
d.0009
Drive voltage size
240 / 460
R
d.000A Reserved
-
d.000b Pressure reference
0 ÷ 1000.0Bar
R
d.000C Measured pressure
0 ÷ 1000.0Bar
R
m
MOTOR
DATA
m1
MOTOR
MAIN PARAMETERS
m.1000 Motor type
‘0 S-r’ = Synchronous rotative
‘1 S-L’ = Synchronous linear
‘2 dC’ = Permanent mag. DC
‘3 U-F’ = Induction V/Hz
‘4 IM’ = Induction FOC
S
m.1001 Rated speed
0 ÷ 20000 RPM
S
m.1002 Rated current
0 ÷ 600.00 A
S
m.1003 Peak current
0 ÷ 600.00 A
S
m.1004 Stall current
0 ÷ 600.00 A
S
m.1005 Rated voltage
10 ÷ 460 V
S
m.1006 Poli motore
2 ÷ 50 poli
S
m.1007 Poli resolver
2 ÷ 16 poli
S
m2
MOTOR
ADVANCED PARAMETERS
m.2000 Phase resistance
0.01 ÷ 650 Ω
S
m.2001 Sync. inductance
0.01 ÷ 650 mH
S
m.2002 I2T Time
1 ÷ 3000 s
S
m.2003
Motor autophasing
command
‘C off = OFF command
‘C on’ = ON command
S
m.2004 Feedback offset
0 ÷ 360.00 °
S
Содержание NTT 240
Страница 129: ......