49
Field Description
second.
•
bits/sec
indicates the average number of bits received per
second.
Last 300 seconds output: 0 bytes/sec, 0
bits/sec, 0 packets/sec
Average output rate over the last 300 seconds, where:
•
packets/sec
indicates the average number of packets sent per
second.
•
bytes/sec
indicates the average number of bytes sent per
second.
•
bits/sec
indicates the average number of bits sent per second.
0 packets input, 0 bytes, 0 drops
Total number and size (in bytes) of the input packets of the
interface and the number of the dropped packets
0 packets output, 0 bytes, 0 drops
Total number and size (in bytes) of the output packets of the
interface and the number of the dropped packets
The brief information of interface(s) under
route mode
Brief information about Layer 3 interfaces
Link: ADM - administratively down; Stby -
standby
Link status:
•
ADM – The interface has been administratively shut down. To
recover its physical state, perform the
undo shutdown
command.
•
Stby – The interface is operating as a backup interface.
Protocol: (s) - spoofing
If the network layer protocol state of an interface is shown as UP,
but its link is an on-demand link or not present at all, its protocol
attribute includes the spoofing flag (an
s
in parentheses).
Interface
Abbreviated interface name
Link
Physical link state of the interface, which can be:
•
UP – The link is up.
•
ADM – The link has been administratively shut down. To
recover its physical state, perform the
undo shutdown
command.
Protocol
Protocol connection state of the interface, which can be UP,
DOWN, or UP(s).
Main IP
The main IP address of the interface
Description
Description of the interface
Cause
The cause of a DOWN physical link. If the port has been shut
down with the
shutdown
command, this field displays
Administratively
. To restore the physical state of the interface,
use the
undo shutdown
command.
NOTE:
Because the S5120-EIseries Ethernet switches do not count the average input/output rate or input/output
packets of a loopback interface, these fields are displayed as “0” in the
display interface loopback