58
6.3 Calibration Error Messages
Message Description
30 F.S.>MAX! The entered calibration weight, together with the currently
applied signal, indicates that the full scale signal will be greater
than the allowed maximum of the indicator. Verify that correct
entries have been made for the scale capacity in
Section 3.3.2
and for the calibration weight. Call a GSE distributor.
31 F.S.<.1mVv The entered calibration weight, together with the currently
applied signal, indicates that the full scale signal will be less than
the allowed minimum of the indicator. Verify the proper entries
for the scale capacity in
Section 3.3.2
and for the calibration
weight. Call a GSE distributor.
32 ADD
MORE!
The applied weight during calibration was less than 0.1% of
capacity. More weight than this is required.
33 ReCALReq'd The just completed calibration is insufficient to guarantee
accurate results due to either the cal weight being less than 5% of
capacity or this was the first calibration of this platform to this
Indicator and, therefore, the coarse gain was adjusted by the
Indicator.
Содержание Agrifeed 5500