18
Parameter Description
Selections
MOTION
SETUP
Defines the amount of instability in terms of
number of divisions that will constitute
motion. Presence of motion will delay ZERO,
TARE or ingredient Auto-Advance until
motion ceases.
0.5, 1-5, 10
divisions,
OFF
*1.0
FILTER
SETUP
Determines how quickly the indicator will
respond to a change in weight. A low
filter setting results in fast response, while
a heavier filter setting will ‘dampen’ the
response. Filtering is used to help
stabilize weight fluctuations due to wind,
vibration, etc.
MINIMUM,
LOW,
*MEDIUM
,
HEAVY,
MAXIMUM
DISPLAY
UPDATE
RATE
Sets the rate at which the weight display is
refreshed.
5/sec, 2/sec,
1 sec, 2 sec
*2/SEC
UNITS
SETUP
Sets the default weight units.
lb, kg, Tons
*lb
* indicates default setup
3.3.3 Communication
Setup
Access the Communication Setup as described in section 3.3.
Table 7
describes the Communication Setup parameters.
SETUP MENU SELECTION
J
COMM SETUP
I
[YES]=Access [NO]=Next [HELP]=Exit
Figure 13: Setup Menu Selection - Comm Setup
To navigate the Communication Setup selections:
1.
Press
[YES]
to advance to the next parameter.
2.
Press
[NO]
to select options within a parameter.
3.
Press
[HELP]
to return to the Setup Menu Selection screen.
4.
Press
[HELP]
again to save changes and exit the setup mode.
Содержание Agrifeed 5500
Страница 10: ...6 This page is intentionally left blank...
Страница 52: ...48 This page is intentionally left blank...
Страница 70: ...31 WI 150 Ultra Low Power Weight Indicator Service Manual...