9
The seal will pass through two back panel screws as shown in
Figure 5
.
Figure 5: Legal for Trade Sealing Method
2.3.2 Audit Trail
Three separate incrementing, non-resetable audit trail parameters are
used to indicate changes to various parameters, P60201 – OIML, P60203
– Calibration , and P60204 – Setup. An audit trail counter will increment
only once upon exiting the Setup Mode and saving changes regardless of
how many settings were changed.
With the indicator off, press and hold
[CLR]
key and turn power on.
Continue to hold
[CLR]
until "
Macro Disbl
" is displayed. Key in
"
60203
" and press
[NET/GROSS]
to view the calibration event counter,
or key in "
60204
" and press [
NET/GROSS
] to view the configuration
event counter. To return to the normal weigh mode from either parameter
"
60203
" or "
60204
", press the
[ZERO]
key.
2.4 Wiring
A description of all wiring terminals is included on the bottom label of
the enclosure as shown in
Figure 6
.
Figure 6: Agrifeed 5500 Connector Label