34
3.3.7.2 Last
Zero
This procedure allows span re-calibration without removing the
applied test weight. The last zero established by pressing
[ZERO]
from the weigh mode will be used as the zero reference for this
procedure.
To access
" Last Zero?"
calibration from the weigh mode:
1.
Remove all weight and press
[NET\GROSS]
then
[ZERO]
to establish a gross zero reference.
2.
Access the Calibration Setup Menu Selection as described
in section 3.3.
3.
Press
[YES]
to access the calibration routines (see Figure
24).
4.
Press
[NET/GROSS]
to scroll to the
“Last Zero?”
calibration method.
5.
With the test weight still on the scale, press
[ENTER]
to
initiate span calibration. The display then shows
"Keyin
CalWt"
.
5.
Place the calibration weight on the platform, key in the
calibration weight and press
[ENTER]
to establish span.
6.
After establishing the span,
“CAL OK?”
is displayed
suggesting that the calibration is acceptable, or
“ReCal
???”
is displayed suggesting that the calibration procedure
be repeated.
Press
[YES]
at the
“CAL OK?”
prompt or
[NO]
at the
“ReCal ???”
prompt to accept the calibration.
OR
Press
[NO]
at the
“CAL OK?”
prompt or
[YES]
at the
“ReCal ???”
prompt to repeat the calibration.
7.
Once the calibration is accepted in step 7, press
[ENTER]
at the
ENTER=SAVE
prompt and again at the
ENTER=EXIT
prompt to save the new calibration and exit
the calibration mode.
To exit the calibration mode without saving the new
calibration, press
[CLR]
at the
ENTER=SAVE
prompt.
Then press
[ENTER]
at the
ENTER=UNDO
prompt and
again at the
ENTER=EXIT
prompt to exit the calibration
mode.