6.2.1 Reload Agrifeed 5500 Custom Program
If you experience a Code 26 error or Code 60 (New Eprom) on the
Agrifeed 5500 unit, the following steps will reload the program back into
the indicator. Please be advised that reloading this program may take
several minutes to complete. All recipe, ingredient and pen information
will be deleted.
1.
First press
[CLR] [CLR]
, then key in
100 [NET\GROSS]
.
2.
The display will prompt
“
Keyin Code”
.
3.
Key in the access code
23640 [ADD RECIPE] [ENTER]
.
4.
Next, key in
65001 [NET\GROSS]
to access the
“Deflt All”
prompt.
5.
Press
[TARE]
to display
“Agri-feed”
.
6.
Press
[ENTER]
to display
“Sure?”
.
7.
After a moment the display will prompt
“Enter=Dflt”
.
8.
Press
[ENTER] [ENTER]
to begin loading the Agrifeed
program.
If the display went right to the Agrifeed start up screen, the following
steps will load the program from the eprom into the indicator. Please be
advised that reloading this program may take several minutes to
complete. All recipe, ingredient and pen information will be deleted.
1.
Turn the unit off, hold down the
[CLR]
key and turn the unit
back on. Hold down the
[CLR]
key until the display reads
“macro disbl”.
2.
Key in
100 [NET\GROSS]
.
3.
The display will prompt
“
Keyin Code”
.
4.
Key in the access code
23640 [ADD RECIPE] [ENTER]
.
5.
Next, key in
65001 [NET\GROSS]
to access the
“Deflt All”
prompt.
6.
Press
[TARE]
to display
“Agri-feed”
.
7.
Press
[ENTER]
to display
“Sure?”
.
8.
After a moment the display will prompt
“Enter=Dflt”
.
9.
Press
[ENTER] [ENTER]
to begin loading the Agrifeed
program.