53
5.2.4 Advancing
Pens
Press
[SELECT INGRED]
to advance to the next pen. This records the
unloaded net weight of the previous pen, deletes the pen from the routing
list, then waits for you to press
[START]
to begin the unload process for
the next pen. When all pens have been deleted from the routing list, the
display prompts “
RECIPE UNLOADED!
”.
When using a pen routing list to unload material, it is possible to
temporarily skip pens by pressing
[SELECT INGRED]
before pressing
[START]
to unload.
Pressing
[STOP]
during the unloading process will record the weight
already unloaded for the current pen, but will not delete it from the
routing list. Thus it is possible to unload the remaining weight out of
sequence at a later time.
Pressing
[STOP]
twice consecutively during the unload process
temporarily exits the routing list. Pens that remain in the routing list are
not deleted. This allows spot feeding for individual pens not included in
the routing list (see section 5.2.1). You can later return to the pen routing
list as described in section 5.2.2.
5.2.5 Unloading using Weight / Animal
If a recipe uses a weight entry method of Weight/Animal, you can unload
material by specifying the number of animals to feed.
To unload using the Weight/Animal entry method:
1.
Make sure the Agrifeed 5500 is in the UNLOAD mode – if it is
in the LOAD mode, press
[UNLOAD]
.
2.
Press
[START BATCH]
.
3.
The batch target is displayed in terms of how many animals can
be fed based on the current gross weight. Key in the number of
animals to feed, up to the maximum number displayed, and
press
[ENTER]
.
4.
The display prompts
“Enter Pen/ID:”
. Key in the pen ID# and
press
[ENTER]
.
5.
Press
[START BATCH]
to begin the unload process.
5.2.6 Unfinished Load / Unload
If the
LOAD
or
UNLOAD
process is stopped without completion, the
function will be highlighted on the display. If a
LOAD
was interrupted
and the [
LOAD/UNLOAD
] key is pressed to switch to
UNLOAD
, the
following prompt will appear: