Model G0841 (Mfd. Since 06/18)
-29-
5. Connect machine to power source (refer to
Power Connection on Page 27). Power
lamp (see
Figure 26) on control panel should
illuminate to indicate power is connected.
6. Twist Emergency Stop button on control panel
clockwise until it pops out (see
Figure 27).
This resets button so machine will start.
4. Push Emergency Stop button on control
panel (see
Figure 26).
Figure 27. Resetting the Emergency Stop
button.
Figure 26. Location of Emergency Stop button
and power lamp.
Emergency
Stop Button
Power
Lamp
7. Push power button (see Figure 28) to enable
power to all motors and electrical systems.
Figure 28. Location of power button.
Power
Button
8. Verify correct 3-phase power supply
polarity by using headstock height switches
(see
Figure 29) to raise and lower headstock.
— If headstock raises when UP button is
pushed and lowers when DOWN button
is pushed, then phase polarity is correct.
Remove related shipping tag from control
panel and continue to
Step 9.
— If headstock lowers when UP button is
pushed and raises when DOWN but-
ton is pushed, then power phase polar-
ity is not correct. Push Emergency Stop
button, disconnect machine from power
source, switch any two of three incoming
power supply wires inside electrical panel
(refer to
Figure 25 on Page 28), then
restart Test Run.
Figure 29. Location of headstock height
switches.