Model G0841 (Mfd. Since 06/18)
-27-
Power Connection
power connection
Figure 21. Connecting power to machine.
Move the disconnect switch handle to the ON
position, as illustrated below. The machine is now
connected to the power source.
Figure 22. Disconnecting power from machine.
Move the disconnect switch handle to the OFF
position, as illustrated below. The machine is now
disconnected from the power source.
Note: Lock the switch in the OFF position to
restrict others from starting the machine.
Before the machine can be connected to the
power source, an electrical circuit and connec-
tion device must be prepared per the
POWER
SUPPLY section in this manual; and all previous
setup instructions in this manual must be com-
plete to ensure that the machine has been assem-
bled and installed properly. The disconnect switch
installed by the electrician (as recommended) is
the primary means for disconnecting or connect-
ing the machine to the power source.
Electrocution, fire, shock,
or equipment damage
may occur if machine is
not properly grounded
and connected to power
supply.
DO NOT use a phase converter to sup-
ply 3-Phase power, as it could damage
or decrease life of electrical components.
Damage caused by running this machine
with a phase converter will not be covered
under warranty.
IMPORTANT: Due to the complexity required
for planning, bending, and installing the conduit
necessary for a code-compliant hardwire setup,
an electrician or other qualified person MUST per-
form this type of installation. Hardwire setups typi-
cally require power supply wires to be enclosed
inside of a solid or flexible conduit, which is
securely mounted at both ends with the appropri-
ate conduit fittings. All work must adhere to the
required electrical codes.
To connect machine to power:
1. Open electrical panel (see Figure 23).
Figure 23. Electrical panel opened.
Electrical
Panel Door
Electrical Panel
Содержание G0841