-28-
Model G0841 (Mfd. Since 06/18)
5. Feed wires through conduit to electrical
panel. Make sure wires have enough slack
inside eletrical panel so they are not pulled
tight or stretched.
6. Connect ground wire to ground terminal (see
Figure 25), then connect incoming power
wires to power terminals (see
Figure 25).
(Refer to G0841 Wiring Manual
for detailed
wiring diagrams.)
Figure 25. Terminal locations to connect ground
wire and incoming power wires.
7. Close and secure electrical panel door, then
perform
Test Run in following section to
verify correct power phase polarity.
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
The Test Run verifies the following: 1) 3-phase
power supply polarity is correct, 2) the Emergency
Stop button safety features work correctly, and 3)
the motors power up and run correctly.
To test run machine:
1. Read and follow safety instructions at begin-
ning of manual, take all required safety pre-
cautions, and make sure all previous setup/
assembly steps in this manual have been
followed and completed.
2. Clear all setup tools and loose items away
from machine.
3. Make sure machine is disconnected from
power source (refer to
Power Connection
on
Page 27).
4. Connect conduit to electrical panel through
access hole (see
Figure 24).
Figure 24. Location of electrical panel access
hole and terminal block.
Access
Hole
Terminal
Block
Ground
Terminal
Power
Terminals
Содержание G0841