Unit Control
Floor ceiling
type
213~2040
1.9~10.8
2.8~16.2
——
Cassette
type
480~1700
4.5~9
6.8~13.7
——
6 Selection of the Water Tank
6.1 Specifications of the Water Tank
SXVD200LCJ/A-K
220~240V-1N-50Hz
A single coil with the electric heater is integrated, used for floor heating system
SXVD300LCJ/A-K
SXVD200LCJ2/A-K
220~240V-1N-50Hz
Dual coils with the electric heater are integrated, used for floor heating system and the solar system
SXVD300LCJ2/A-K
SXVD200LCJ/A-M
380~415V-3N-50Hz
A single coil with the electric heater is integrated, used for floor heating system
SXVD300LCJ/A-M
SXVD200LCJ2/A-M
380~415V-3N-50Hz
Dual coils with the electric heater are integrated, used for floor heating system and the solar system
6.2 Volume Selection of the Water Tank
6.2.1 Selection Based on Water Consumption Per Capita
Building Type
Unit
Daily Water Consumption (L)
Water Temperature (°C)
House
Per person, Per day
40~80
60
Villa
Per person, Per day
70~110
60
6.2.2 Selection Based on Sanitary Utensils
Utensil Type
Daily Water
Consumption (L)
Water Temperature (°C)
Bathtub, Sprinkler system (with shower)
150
40
Bathtub, Sprinkler system (without shower)
125
40
Shower
70~100
37~40
Wash Basin
3
30
6.2.3 Selection of the Water Tank
Selection of the water tank should consider the flow rate of the shower head, duration of use per
person and daily water consumption.
Содержание VERSATI III Series
Страница 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Страница 5: ...Engineering Data ENGINEERING DATA ...
Страница 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Страница 22: ...Design and Selection DESIGN SELECTION ...
Страница 33: ...Unit Control UNIT CONTROL ...
Страница 72: ...Unit Control ...
Страница 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Страница 77: ...Unit Control 2 Click Func at the left lower corner in device operation interface to enter advanced settings ...
Страница 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Страница 80: ...Unit Control ...
Страница 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Страница 82: ...Installation UNIT INSTALLATION ...
Страница 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Страница 117: ...Test Operation Troubleshooting Maintenance 3 Flow Chart of Troubleshooting 3 1 Comp High pressure Protection E1 ...
Страница 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Страница 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Страница 120: ...Test Operation Troubleshooting Maintenance 3 4 Overload Protection of Compressor or Driver Error ...
Страница 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Страница 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Страница 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Страница 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...
Страница 127: ...Test Operation Troubleshooting Maintenance ...
Страница 135: ...Test Operation Troubleshooting Maintenance ...