Test Operation & Troubleshooting & Maintenance
44
Sensing circuit error or current sensor error
Current sen.
LF
45
Desynchronizing
Desynchronize
Pc
46
Compressor stalling
Comp. stalling
H7
47
Communication error
drive-main com.
LE
48
Radiator or IPM or PFC module overtemperature
Overtemp.-mod.
P8
49
Radiator or IPM or PFC module temperature sensor error
T-mod. sensor
P7
50
Charging circuit error
Charge circuit
Pu
51
Incorrect AC voltage input
AC voltage
PP
52
Drive board temperature sensor error
Temp-driver
PF
53
AC contactor protection or input zero crossing error
AC contactor
P9
54
Temperature drift protection
Temp. drift
PE
55
Current sensor connection protection (current sensor not
connected to phase U/V)
Sensor con.
PD
56
Communication error to the outdoor unit
ODU Com.
E6
57
Communication error to the indoor unit
IDU Com.
E6
58
Communication error to the drive
Driver Com.
E6
59
Solar kit-superheating
Solarsuperheat
F6
Содержание VERSATI III Series
Страница 1: ...VERSATI Ⅲ Air To Water Heat Pump ...
Страница 5: ...Engineering Data ENGINEERING DATA ...
Страница 10: ...Engineering Data 1 4 Operating Principle 1 4 1 Schematic Diagram ...
Страница 22: ...Design and Selection DESIGN SELECTION ...
Страница 33: ...Unit Control UNIT CONTROL ...
Страница 72: ...Unit Control ...
Страница 76: ...Unit Control 3 3 2 Setting of Main Functions 1 Set mode and temperature ...
Страница 77: ...Unit Control 2 Click Func at the left lower corner in device operation interface to enter advanced settings ...
Страница 79: ...Unit Control 3 3 3 2 Help Click Help and view the operation instructions of the APP ...
Страница 80: ...Unit Control ...
Страница 81: ...Unit Control 3 3 3 3 Feedback Click Feedback to submit feedback ...
Страница 82: ...Installation UNIT INSTALLATION ...
Страница 113: ...Test Operation Troubleshooting Maintenance TEST OPERATION TROUBLESHOOTING MAINTENANCE ...
Страница 117: ...Test Operation Troubleshooting Maintenance 3 Flow Chart of Troubleshooting 3 1 Comp High pressure Protection E1 ...
Страница 118: ...Test Operation Troubleshooting Maintenance 3 2 Comp Low pressure Protection E3 ...
Страница 119: ...Test Operation Troubleshooting Maintenance 3 3 Comp Discharge Temp Protection E4 ...
Страница 120: ...Test Operation Troubleshooting Maintenance 3 4 Overload Protection of Compressor or Driver Error ...
Страница 121: ...Test Operation Troubleshooting Maintenance 3 5 DC Fan Error EF 3 6 Temperature Sensor Error ...
Страница 122: ...Test Operation Troubleshooting Maintenance 3 7 Communication Malfunction E6 ...
Страница 123: ...Test Operation Troubleshooting Maintenance 3 8 Capacity Switch Error Code C5 ...
Страница 125: ...Test Operation Troubleshooting Maintenance IPM or PFC Over temperature Protection Code P8 ...
Страница 127: ...Test Operation Troubleshooting Maintenance ...
Страница 135: ...Test Operation Troubleshooting Maintenance ...