58
Local Control Using the Densité Frame Control Panel
Setting the Card’s IP Addresses
[ESC]Cancels parameter value changes that have not been confirmed and reverts the
parameter to its former value.
Returns to the previous menu. In the main menu, [ESC] does
not
exit the menu system. To
exit, push the [SELECT] button on the card being controlled.
If no controls are operated for 30 seconds, the controller reverts to its normal standby
status, and the selected card’s status reverts to its normal operating mode.
The complete menu structure is shown in
Setting the Card’s IP Addresses
Only make changes to the Ethernet settings during off hours as any settings change will
take the card offline for up to 30 seconds.
Push the SELECT button on the XIP
-
page 35) to assign the local control panel to operate the XIP
-
3901.
• The STATUS LED on the XIP
-
3901 card edge flashes yellow.
Use the control panel buttons to navigate through the menu. The menu allows you to view
and set the UPC
-
3901 card’s current:
•
MANAGEMENT
Ethernet port IP address.
•
SFP1
and
SFP2
Ethernet port IP addresses that you use for media streams.
See also the
Network
, Interface tab.
The Ethernet port configuration parameters are:
• The Ethernet port’s current operating mode: DHCP or DISABLE.
• The Ethernet port’s current IP Address: when mode is set to DISABLE, set the card’s IP
address.
• The Ethernet port’s current subnet Mask: when mode is set to DISABLE, set the subnet
mask for your network.
• The Ethernet port’s current default Gateway: When mode is set to DISABLE, set the
network switch’s IP address.
The XIP
-
3901 will reboot once you have changed a network parameter when:
• Densité local control is removed from the card or,
• You navigate back to the top level menu. You can change all network parameters in one
shot (without the unit rebooting for every parameter change) by staying at a menu
To Configure
See also the Network > Interface tab
XIP
-
3901
-
UC,
XIP
-
3901
-
DC, or
XIP
-
3901
-
FS
XIP
-
3901
-
UDC
-
IP
XIP
-
3901
-
UDC-IF
XIP
-
3901
-
GB-IP
XIP
-
3901
-
JPEG-XS
Содержание XIP-3901
Страница 1: ...XIP 3901 AGILE SDI IP PROCESSING PLATFORM User Manual 13 03065 010 AL M00 2021 08 04 ...
Страница 16: ...16 Table of Contents ...
Страница 18: ...18 Introduction to the XIP 3901 Agile SDI IP Processing Platform ...
Страница 60: ...60 Local Control Using the Densité Frame Control Panel Setting the Card s IP Addresses ...
Страница 65: ...65 XIP 3901 User Manual The iControl panel for the card then shown ...
Страница 113: ...113 XIP 3901 User Manual Figure 7 25 Options Panel Shown on XIP 3901 UC ...
Страница 114: ...114 Configuring the XIP 3901 UC DC FS Applications with iControl Options Panel ...
Страница 152: ...152 Configuring the XIP 3901 UDC IP v1 2 Application with iControl Metadata Panel Figure 8 21 Metadata panel ...
Страница 168: ...168 Configuring the XIP 3901 UDC IP v1 2 Application with iControl Options Panel ...
Страница 190: ...190 Configuring the XIP 3901 UDC IF v3 0 Application with iControl UDC1 UDC2 Tab Figure 9 14 HDR UDC1 UDC2 Tab ...
Страница 198: ...198 Configuring the XIP 3901 UDC IF v3 0 Application with iControl Metadata Panel Figure 9 16 Metadata panel ...
Страница 202: ...202 Configuring the XIP 3901 UDC IF v3 0 Application with iControl Inputs Tab Figure 9 18 Audio Inputs Tab ...
Страница 280: ...280 Configuring the XIP 3901 JPEG XS v1 0 Application with its Web Interface Technical Support Panel ...
Страница 290: ...290 Maintenance Troubleshooting Keep Fiber Connections Clean ...
Страница 298: ...298 Installing the SFP Ethernet Module Removing the SFP module ...
Страница 307: ...307 XIP 3901 User Manual ...