Maintenance & Troubleshooting
Cooling Fan Operational Assessment
Replacing a rear panel
To replace a rear panel in a Densité frame
1 If a card is already installed in a modular card slot served by the rear panel you are
changing, remove it first (see
2 Remove the existing rear panel (either blank or belonging to an existing card) by
releasing the captive screws at the bottom.
There may be several captive screws, depending on the card type.
3 Position the new panel and secure it in place with the captive screw(s) at the bottom.
Removing a card
To remove a card
1 Open the front door of the frame.
2 Lift up the card ejector handle on the front of the card you want to remove, to lever the
connectors apart, and then use the handle to pull the card straight out of the modular
card slot.
3 Close the front door of the frame.
Installing a Card
See
Installation of the Rear Connector Panel and Card
Cooling Fan Operational Assessment
A cooling fan has moving parts that, over time, can wear out. In the final stages of fan wear
out, the fan makes a distinctive sound and it rotates at a slower speed, thereby reducing
airflow which undermines its ability to remove heat from the XIP
-
3901. Under this
condition, fan replacement is required.
Also, dust contained in the ambient air can accumulate on the fan and on surfaces around
the fan and heatsink, thereby reducing airflow, and preventing air from coming into direct
contact with the heatsink surfaces which undermines the ability to remove heat from the
XIP
-
3901. Under this condition, cleaning is necessary and fan replacement may be required.
Some diagnostic procedures may interrupt normal system operation. Changing the
XIP
-
3901’s cooling fan will interrupt normal system operation. Down time can be minimized
by swapping in another known good XIP
-
3901 to restore system operation quickly.
Schedule these maintenance operations during off hours when the system is not in use.
Diagnostics
The XIP
-
3901’s electronic circuitry generates heat that must be shed by forcing air to move
across heat-generating components. Reduced air flow or high ambient temperature results
in heat build-up within temperature-sensitive components within the XIP
-
3901. This can
cause unexpected behavior such as glitches or even a system freeze or shutdown. The
Note:
The rear panel must be installed before the card. See
Содержание XIP-3901
Страница 1: ...XIP 3901 AGILE SDI IP PROCESSING PLATFORM User Manual 13 03065 010 AL M00 2021 08 04 ...
Страница 16: ...16 Table of Contents ...
Страница 18: ...18 Introduction to the XIP 3901 Agile SDI IP Processing Platform ...
Страница 60: ...60 Local Control Using the Densité Frame Control Panel Setting the Card s IP Addresses ...
Страница 65: ...65 XIP 3901 User Manual The iControl panel for the card then shown ...
Страница 113: ...113 XIP 3901 User Manual Figure 7 25 Options Panel Shown on XIP 3901 UC ...
Страница 114: ...114 Configuring the XIP 3901 UC DC FS Applications with iControl Options Panel ...
Страница 152: ...152 Configuring the XIP 3901 UDC IP v1 2 Application with iControl Metadata Panel Figure 8 21 Metadata panel ...
Страница 168: ...168 Configuring the XIP 3901 UDC IP v1 2 Application with iControl Options Panel ...
Страница 190: ...190 Configuring the XIP 3901 UDC IF v3 0 Application with iControl UDC1 UDC2 Tab Figure 9 14 HDR UDC1 UDC2 Tab ...
Страница 198: ...198 Configuring the XIP 3901 UDC IF v3 0 Application with iControl Metadata Panel Figure 9 16 Metadata panel ...
Страница 202: ...202 Configuring the XIP 3901 UDC IF v3 0 Application with iControl Inputs Tab Figure 9 18 Audio Inputs Tab ...
Страница 280: ...280 Configuring the XIP 3901 JPEG XS v1 0 Application with its Web Interface Technical Support Panel ...
Страница 290: ...290 Maintenance Troubleshooting Keep Fiber Connections Clean ...
Страница 298: ...298 Installing the SFP Ethernet Module Removing the SFP module ...
Страница 307: ...307 XIP 3901 User Manual ...