Common Configuration iControl Panels
Status/Name
Status/Name
This column contains an expandable tree listing all the alarms reported by this
XIP
-
3901card.
• Each alarm name includes an icon that shows its current status.
• Some alarms may be text-only, and the alarm status is shown in the name and not by a
status icon.
Card LED, Overall Alarm and GSM Contribution
These columns contain pulldown menus used to set the severity level of each individual
alarm to the alarm named in the column heading. This can be set independently for Card
LED, Overall Alarm and GSM Contribution.
Card LED
This column is used to set the severity level of the selected individual alarm to the status
LED located on the front card-edge. The Card LED status is shown at the bottom of the
alarm tree in the Status/Name column. If at least one Critical or Major alarm is triggered, the
LED will change to red. If no Critical or no Major alarms are triggered and Minor alarms are
occurring, the LED will change to yellow.
Overall Alarm
This column is used to set the severity level of each individual alarm to the Overall Alarm
associated with the card. The Overall Alarm is shown in the upper left corner of the iControl
panel and also appears at the bottom of the Status/Name column.
GSM Contribution
This column is used to set the severity level of each individual alarm to the GSM Alarm
Status associated with this card. GSM is a dynamic register of all iControl system alarms and
is also an alarm provider for external applications. The possible values for this contribution
are related to the Overall Alarm contribution:
• If the Overall Alarm contribution is Disabled, the GSM alarm contribution can be set to
any available value.
• If the Overall Alarm contribution is any level other than Disabled, the GSM contribution
is forced to follow the Overall Alarm.
Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for
troubleshooting and identifying event sequences. Check the box to log alarm events for
each individual alarm.
Содержание XIP-3901
Страница 1: ...XIP 3901 AGILE SDI IP PROCESSING PLATFORM User Manual 13 03065 010 AL M00 2021 08 04 ...
Страница 16: ...16 Table of Contents ...
Страница 18: ...18 Introduction to the XIP 3901 Agile SDI IP Processing Platform ...
Страница 60: ...60 Local Control Using the Densité Frame Control Panel Setting the Card s IP Addresses ...
Страница 65: ...65 XIP 3901 User Manual The iControl panel for the card then shown ...
Страница 113: ...113 XIP 3901 User Manual Figure 7 25 Options Panel Shown on XIP 3901 UC ...
Страница 114: ...114 Configuring the XIP 3901 UC DC FS Applications with iControl Options Panel ...
Страница 152: ...152 Configuring the XIP 3901 UDC IP v1 2 Application with iControl Metadata Panel Figure 8 21 Metadata panel ...
Страница 168: ...168 Configuring the XIP 3901 UDC IP v1 2 Application with iControl Options Panel ...
Страница 190: ...190 Configuring the XIP 3901 UDC IF v3 0 Application with iControl UDC1 UDC2 Tab Figure 9 14 HDR UDC1 UDC2 Tab ...
Страница 198: ...198 Configuring the XIP 3901 UDC IF v3 0 Application with iControl Metadata Panel Figure 9 16 Metadata panel ...
Страница 202: ...202 Configuring the XIP 3901 UDC IF v3 0 Application with iControl Inputs Tab Figure 9 18 Audio Inputs Tab ...
Страница 280: ...280 Configuring the XIP 3901 JPEG XS v1 0 Application with its Web Interface Technical Support Panel ...
Страница 290: ...290 Maintenance Troubleshooting Keep Fiber Connections Clean ...
Страница 298: ...298 Installing the SFP Ethernet Module Removing the SFP module ...
Страница 307: ...307 XIP 3901 User Manual ...