65
UCP
-
3901
User Manual
Fig. 5-2: Connecting to UCP
-
3901 Card RollCall Templates from RollCall Control Panel
8 To configure the multiviwer, see
Getting Started with the Multiviewer
Connecting to the Multiviewer SDC with RollCall for IQUCP25 / IQUCP50
Card
The Multiviewer SDC consists of two configuration components to which you have to make
separate connections. By default, you connect with RollCall to the:
• IQUCP25 / IQUCP50 card at the IQ modular chassis IP address, at port 2050 (default).
• Multiviewer SDC at the
SFP1
IP address, at port 2051.
PREREQUISITE: The Multiviewer SDC license must have been installed.
1 Connect to the IQUCP25 / IQUCP50 card through it default port 2050. See
3901 / IQUCP25 / IQUCP50 Card with RollCall
2 Navigate to the high-speed Ethernet configuration pages for SFP1 and SFP2. See
3 Set the IQUCP25 / IQUCP50’s IP address for the
SFP1
and
SFP2
Ethernet port IP
addresses.
4 Click
Connect to RollCall Network
button in the main toolbar.
5 Using RollCall, connect to the UCP
-
3901’s
SFP1
IP address, at port 2051.
Содержание IQUCP25
Страница 8: ...8 Notices ...
Страница 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Страница 48: ...48 IQUCP Card Installation and Operation Rear Panel and Connectors IQUCP5001 3B3 IQUCP5002 2B3 IQUCP5003 3B3 ...
Страница 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Страница 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Страница 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Страница 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Страница 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...
Страница 308: ...308 Multiviewer SDC Timer Request Protocol ...