161
UCP
-
3901
User Manual
Address
Enter the destination RollCall address for the selected RollTrack
Output
Index
.
The address may be changed by typing the new destination into the
text field, then clicking
to save the selection. Clicking
returns
to the default preset destination.
The RollTrack address consists of four sets of numbers, for example,
0000:10:01*99
:
• The first set,
0000
, is the network segment code number.
• The second set,
10
, is the number identifying the
(enclosure/mainframe) unit.
• The third set,
01
, is the slot number in the unit.
• The fourth set,
99
, is a unique identifier number that you define
for the destination unit in a multi-unit system. This ensures only
the correct unit will respond to the command. If left at
00
, an
incorrectly fitted unit may respond inappropriately.
Command
This item enables a command to be sent to the selected destination
unit. Enter the RollCall command (RollCall command number and
command value) for the selected RollTrack Output
Index
destination.
The command may be changed by typing a code into the text field,
and then selecting
to save the selection. Clicking
returns to
the default preset command.
A RollTrack command consists of two sets of numbers, for example:
84:156
:
The first number,
84
, is the actual RollTrack command.
The second number,
156
, is the value sent with the RollTrack
command.
Sending
A message is displayed here when the unit is actively sending a
RollTrack command. Possible messages are:
String:
A string value is beingsent.
Number:
A number value is beingsent.
No:
The message is not being sent.
Yes:
The message is being sent.
Status
A message is displayed here to indicate the status of the currently
selected RollTrack index. Possible RollTrack Status messages are:
OK:
RollTrack message was sent and received successfully.
Unknown:
RollTrack message has been sent but transmission has not
yet completed.
Timeout:
RollTrack message has been sent but acknowledgment not
received. This could be because the destination unit is not at the
location specified.
Error:
RollCall error.
Bad:
Broken RollCall packet.
Disabled:
RollTrack sending is disabled.
Parameter
Description
Содержание IQUCP25
Страница 8: ...8 Notices ...
Страница 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Страница 48: ...48 IQUCP Card Installation and Operation Rear Panel and Connectors IQUCP5001 3B3 IQUCP5002 2B3 IQUCP5003 3B3 ...
Страница 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Страница 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Страница 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Страница 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Страница 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...
Страница 308: ...308 Multiviewer SDC Timer Request Protocol ...