Documentation HG G-73650ZD | English, Revision 05 | Date: 09.03.2017 | www.goetting-agv.com
126
Chapter 7: Feldbus Protocol
7.2 Rx Reception Telegram PLC –> Control Unit
Byte Nr Order Type
Name
Explanation
0
–
Byte
Requested Mode
– 0 = manual driving
– 1 = automatic driving
– 2 = Remote control
– 3 = Parameter Test only via Website
– 4 = Vector steering
1
–
Byte
Command
– bit-3: –
– bit-4: –
– bit-5: Error Acknowledge
– bit-6: Emergency Stop active
– bit-7: Emergency Stop acknowledge
2
H
word
Speed Limitation
Format: 16-bit
Resolution: 1 mm/s
Value range: 1..65535mm/s
Value 0: Speed Limit not used
Offset: 0
3
L
4
–
–
–
spare
5
–
Byte
Request Count of Error
Counter modulo 2 bit (Bit 0 and 1)
6
–
Byte
Request Count of Seg-
ment Search
Counter modulo 8 bit
7
–
–
–
spare
8
H
Word
Segment Command
– bit-0 release segment 0
– bit-9 Segment search request
9
L
10
H
Word
Stop Distance
Format: 16-bit
Resolution: 1 mm
Value range: 1..65535mm
Value 0: Stop Distance not used
Offset: 0
11
L
12
–
–
–
spare
13
–
–
–
spare
14
H
Word
Target Segment Table 0
– Target Segment Table
15
L
16
H
Word
Target Segment Table 1
17
L
18
H
Word
Target Segment Table 2
19
L
20
H
Word
Target Segment Table 3
21
L
22
H
Word
Target Segment Table 4
23
L
24
H
Word
Target Segment Table 5
25
L
26
H
Word
Target Segment Table 6
27
L
28
H
Word
Target Segment Table 7
29
L
Table 49