Documentation HG G-73650ZD | English, Revision 05 | Date: 09.03.2017 | www.goetting-agv.com
88
Chapter 5: Commissioning
Link
You can download the file
parameter_default.txt
from the site
and load it into the navigation controller (see section 4.5 on
page 77). In that case, all of the parameters listed below for the example are set appropri-
ately.
5.4.1 Configuration -> Main
Parameter
Value
Explanation
Trigger Level Digital Inputs
12V
Decision threshold low / high to 12V
Trigger Level Encoder Inputs 12V
Decision threshold low / high to 12V
Vehicle Type
Omnidrive 0
A universal omnidirectional vehicle with properties that
are specified via the parameterisation of the wheels is
used as the basis for almost all vehicles.
Vehicle Number
1
Vehicle number (for assignment in the case of several
vehicles)
CAN1 Protocol
CAN Universal
To date, this is the only available protocol
CAN1 Baudrate
250
Baud rate for the CAN 1 connector slot
CAN2 Protocol
disabled
Not yet available. CAN messages of the wheels can still
be placed on CAN 2
CAN2 Baudrate
250
Baud rate for the CAN 2 connector slot
Send Fusion
On
The sending of the position, alignment and speed on
the CAN bus can be controlled here
Log Seg End
On
Once a segment end is reached, it is recorded, even if
the vehicle rolls back
Sensor Fusion
Int. Transponder The vehicle is to move with the help of a transponder
antenna: No GPS and no external position sensor.
Simulation
On
This is enabled for the moment in order to be able to
carry out the simulation in this description.
However,
it must be disabled later to be able to control a
vehicle.
Resolution Segments
0.001
The resolution of the test segments is 1 mm (more
manageable). To minimise rounding errors in the case
of segments that are not located in the direction of a
co-ordinate axis or curves,
a resolution of 0.1 mm
(0.0001) should be selected for the real seg-
ments later here and in the CAD program
.
Year
15
Current year (without 2000). The date is important for
recording data on a USB stick
Month
12
Current month
Day
18
Current day
Hour
14
Current hour
Minute
20
Current minutes
Second
29
Current second
Table 15
Example commissioning parameters in Config. Main