Documentation HG G-73650ZD | English, Revision 05 | Date: 09.03.2017 | www.goetting-agv.com
122
Chapter 7: Feldbus Protocol
7
Feldbus Protocol
The optional Feldbus module (s. section 3.6 on page 42) enables telegram output via e.g.
Profinet or Profibus. The following tables show the telegram structure.
7.1 Tx Transmission Telegram Control Unit –> PLC
Byte Nr Order Type
Name
Explanation
0
–
Byte
Operation Mode
– 0 = manual driving
– 1 = automatic driving
– 2 = Remote control
– 3 = Parameter Test (only via Website, s.
– 4 = Vector steering absolute
– 5 = Vector steering relative
1
–
–
–
spare
2
H
Word
Attribute
Bit 17-32 of the Segment Attribute at the
actual Segment at the actual Point
3
L
4
–
–
–
spare
5
–
–
–
spare
6
–
–
–
spare
7
–
–
–
spare
8
H
Word
Segment Status
– bit-8: –
– bit-9: Segmentsearch active
– bit-10: Segmentsearch finished
9
L
10
H
Word
Number of Points
Number of Points in the actual Segment
11
L
12
H
Word
Actual Point Number
Actual Point Number of the actual segment
13
L
14
H
Word
Segment Table 0
– Actual Segment Table or
– during Segment search Search Result
depending on Segment Page
15
L
16
H
Word
Segment Table 1
17
L
18
H
Word
Segment Table 2
19
L
20
H
Word
Segment Table 3
21
L
22
H
Word
Segment Table 4
23
L
24
H
Word
Segment Table 5
25
L
26
H
Word
Segment Table 6
27
L
28
H
Word
Segment Table 7
29
L
Table 48
Feldbus Protocoll Tx Telegram Control Unit –> PLC (part 1 of 4)