61
Error / Failure
Meaning
Correction
32
EEPROM failure
Firmware memory chip
not functioning.
Restore factory defaults.
1.
Turn off power.
2.
While holding down F1
and CANCEL keys, turn
on power.
3.
Retry.
Call Field Service if retry fails.
33
X axis overload
Motion along axis is
jammed or obstructed.
Clear the jam. Retry. Call Field
Service if retry fails.
34
X2 axis overload
Motion along axis is
jammed or obstructed.
Clear the jam. Retry. Call Field
Service if retry fails.
35
Y axis overload
Motion along axis is
jammed or obstructed.
Clear the jam. Retry. Call Field
Service if retry fails.
36
Z axis overload
Motion along axis is
jammed or obstructed.
Clear the jam. Retry. Call Field
Service if retry fails.
37
? axis overload
Unused test
N/A
38
X axis home error
Unused test
N/A
39
Z axis home error
40
Y axis home error
Axis cannot move to
home position.
Excessive friction or
obstruction.
Remove any obstacles to axis
movement.
Retry.
Call Field Service if retry fails.
41
Data overflow error
42
Communications
overrun error
43
Communications
parity error
Invalid, incorrect, or
incompatible
communication setting.
Check communication setting
for compatibility with
computer.
44
Communications
framing error
Invalid, incorrect, or
incompatible
communication setting.
Check communication setting
for compatibility with
computer.
45
No pinch wheel
found
Pinch wheel sensor
malfunction.
Pinch wheel assembly is
loose.
Retry.
Call Field Service if retry fails.
46
Pinch wheel sensor
failure
Pinch wheel sensor
malfunction.
Retry.
Call Field Service if retry fails.
Содержание ODYSSEY XP
Страница 1: ...Owner s Guide ...
Страница 4: ......