No.
Designation
Tightening torque
Comments
26
Sound absorber
2.0 Nm
Sealed opening to the
atmosphere
57
Screws, pneumatic
block
1.5 Nm
66
Screws, solenoid
valves
0.8 Nm
10.4.1 Install pneumatic and external connections
Fig.50
No.
Designation
Tightening torques
6
Screw-in plug connection
2.0 Nm
21
Sound absorber
2.0 Nm
22
Locking screw
0.5 Nm
23
Plug
24
Cable gland
2.5 Nm
26
Sound absorber
2.0 Nm
Carry out the following steps:
1.
Fit the screw-in push-in connector (6), sealing plug (23) and locking screw
(22) according to the markings on the control top.
2.
Fit the cable gland (24).
®
The pneumatic and external connections are mounted.
®
Done
10.4.2 Fitting the Pneumatic Block
Requirement:
•
When fitting the pneumatic block, make sure that it is compatible!
•
Insert the journal (8.1) on the pneumatic block into the groove of the base (5)!
Servicing
Installation
430BAL013985EN_6
25.04.2023
95
Содержание T.VIS E-20
Страница 6: ...430BAL013985EN_6 6 25 04 2023...
Страница 9: ...flowcomponents gea com www gea com General Information Contact 430BAL013985EN_6 25 04 2023 9...
Страница 84: ...Fig 42 X signal curve sensor Y current course curve LED brightness Start up 430BAL013985EN_6 84 25 04 2023...
Страница 108: ...14 Dimension sheet control top T VIS E 20 Fig 58 Dimension sheet control top T VIS E 20 430BAL013985EN_6 108 25 04 2023...
Страница 112: ......