4.
To adjust tolerance depending on the valve type from the beginning of LED B
illumination, complete the necessary spindle rotation by turning to the left
(anti-clockwise) in accordance with Table 1 to add the necessary tolerance
allowance (green line in Fig. 37).
®
The light intensity of LED B changes.
5.
Loosen lock nut M5 S2.1 using jaw wrench AF 8 in clockwise direction.
®
Sensor S2 is adjusted with tolerance.
®
Reset valve actuation, LED B goes out and LED A lights up green.
Fig.39:
X = signal curve sensor / Y = current course curve (LED brightness)
7.5.2
Spring-opening valves
This chapter describes the adjustment of the sensor for the following valves:
–
VARIVENT, ECOVENT, STERICOM valves except valve type U for actuator
selection "A or NO": rest position of the valve spring-closing
–
VARIVENT valve type U with actuator selection "Z or NC": rest position of the
valve spring-opening
–
VESTA valves with actuator selection "A or NO": rest position of the valve
spring-closing
–
In-Line Sprayer IS 25
–
Butterfly and leakage butterfly valve
The as-delivered state of the T.VIS-E-20 is executed as a single-head delivery
without valves as''spring-closing” wiring. The wiring of the sensors S1 and S2
must be changed as follows for spring-opening valves:
Start-up
Adjusting sensors on the control top
430BAL013985EN_6
25.04.2023
79
Содержание T.VIS E-20
Страница 6: ...430BAL013985EN_6 6 25 04 2023...
Страница 9: ...flowcomponents gea com www gea com General Information Contact 430BAL013985EN_6 25 04 2023 9...
Страница 84: ...Fig 42 X signal curve sensor Y current course curve LED brightness Start up 430BAL013985EN_6 84 25 04 2023...
Страница 108: ...14 Dimension sheet control top T VIS E 20 Fig 58 Dimension sheet control top T VIS E 20 430BAL013985EN_6 108 25 04 2023...
Страница 112: ......