6.3.1
Control Top with 1 Solenoid Valve or Without Solenoid Valve
Fig.14:
Control top (standard variant in IP 66)
E1
Exhaust air of the main stroke Y1 (sound absorber or exhaust air
throttle, optional)
Connection E1 must not be closed!
E2
Safety vent against excess pressure and exhaust air of lifting
actuators Y2 and Y3
Connection E2 must not be closed!
P
Central air supply with integrated filter
optional: supply air throttle
N
not available
Y1
Air connection for external main stroke connection
with plug (23)
23
Plug
Control air pressure can be present at the plugs for the air
connections!
Before removing a sealing plug (23), make sure that the respective
air connection is pressure-free!
On most of the GEA Tuchenhagen valve types, solenoid valve Y1 internally
guides the main control air through the switch bar into the main actuator. The
external air connection Y1 is provided in addition.
Assembly and installation
Pneumatic connections
430BAL013985EN_6
48
25.04.2023