5.2.4
Delivery and input data
Hint!
Electrical connections in chapter 6.4 must be observed.
Observe terminal assignment and designation in relation to order
code, see chapter 6.4
5.2.4.1 Pilot valve for pneumatic valves
Intrinsically safe wiring
Errors in the intrinsically safe wiring can lead to serious explosions.
► PLEASE OBSERVE THE TERMINAL DESIGNATION IN CHAPTER
6.4.3.2 (PAGE 48) FOR INTRINSICALLY SAFE WIRING.
Type designation: 512-174 / 512-177
Technical data:
Designation
Description
Type
24 VDC: BATX10 – 1 – 1 – 4
12 VDC: BATX10 – 2 – 1 – 4
Nominal and supply voltage UV
12 VDC or 24 VDC (+/-10%)
Operating currents
– per solenoid valve 12V DC
– per solenoid valve 24V DC
– max. feedback load
50 mA**
25 mA**
2.1 mA
Total
approx. 52 mA**
Technical data: Inputs for solenoid valve activation 24 VDC
Designation
Description
Control voltage
max. 24 VDC +/-10%
Current consumption, solenoid valve
25 mA**
Pull-in voltage
19.2 VDC
Minimum switching current
18.5 mA
Short-circuit protection
no
Nominal power
0.6 W
Resistance
1028 Ω
Technical data and operating conditions
Technical data
430BAL013985EN_6
25.04.2023
41
Содержание T.VIS E-20
Страница 6: ...430BAL013985EN_6 6 25 04 2023...
Страница 9: ...flowcomponents gea com www gea com General Information Contact 430BAL013985EN_6 25 04 2023 9...
Страница 84: ...Fig 42 X signal curve sensor Y current course curve LED brightness Start up 430BAL013985EN_6 84 25 04 2023...
Страница 108: ...14 Dimension sheet control top T VIS E 20 Fig 58 Dimension sheet control top T VIS E 20 430BAL013985EN_6 108 25 04 2023...
Страница 112: ......