Fig.34
Fig.35
2.
Screw the switch bar (4) Mat. 221-589.87, into the piston rod (A4.1) and
tighten with open-end wrench SW 13, torque 3 Nm.
3.
Fit the control top (B) over the switch bar (4) and on the actuator.
4.
Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.
5.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
!
On ASEPTOMAG valves, internal air guiding is not possible. Therefore
connect the air connection (Y1) on the control top and the connection (A.4.2)
on the actuator to the air hose (L).
6.
Connect the pneumatic hose, or 2-3 hoses for valves with seat lifting, in
accordance with the hose connection diagram for the valve.
7.
Carry out commissioning, see Chapter 7, Page 74.
®
Done.
6.6.8
Replacing Control Tops
When replacing the control top observe the following warning note:
Caution!
Spring tension being released if the wrong switch bar is used
When a valve is used with the wrong type of switch bar, there is a risk of
injury as the spring tension can suddenly be released.
► When replacing a predecessor model with a control top T.VIS E-20 the
switch bar must always be replaced!
Assembly and installation
430BAL013985EN_6
25.04.2023
73
Содержание T.VIS E-20
Страница 6: ...430BAL013985EN_6 6 25 04 2023...
Страница 9: ...flowcomponents gea com www gea com General Information Contact 430BAL013985EN_6 25 04 2023 9...
Страница 84: ...Fig 42 X signal curve sensor Y current course curve LED brightness Start up 430BAL013985EN_6 84 25 04 2023...
Страница 108: ...14 Dimension sheet control top T VIS E 20 Fig 58 Dimension sheet control top T VIS E 20 430BAL013985EN_6 108 25 04 2023...
Страница 112: ......